Configuring the EPW 400
OM 100.EPW 400.202002.en
85
Note: Firmware version EPW 400
Up to EPW
400 version V1.06 the outputs of switching points SP1-
SP3 are only updated while measurement is in progress.
From EPW
400 version V1.07 onwards, the outputs of switching
points SP1-SP3 are constantly updated.
6.2.35 Configuration I/O
In this window you may fix the switching function of the digital outputs 3,
4 and 7 as well as of the digital input 13:
Selection
Function
Output 3:
Switching point 1
Refer to switching points
Release
Change condition at NOK or reset
Output 4:
Switching point 2
Refer to switching points
NOK buzzer
Change switching state if NOK,
For activation see 'Evaluation options'
Output 7:
Switching point 3
Refer to switching points
Warning piece
counter
Change of the switching condition when
reaching the taught-in number in the order
counter, view counter or tool counter.
Input 13:
TDC sensor
For activation see 'Evaluation options'
Authorization bit 0
After activation, the user level can be se-
lected from a control system.
Reset
For activation see 'Evaluation options'
The switching logic can be switched between the settings 'High' and 'Low'.