6.2.19 Offset limit of distance sensor
The offset limit is used set the maximum tolerated offset to 10%, 20% or 100% of the
nominal distance.
Offset adjustment for sensor with normal signal output:
TOX
®
standard sensor: 10% (20% possible for compensation)
By tapping on the input field behind 'Offset limit', the value of the offset limit can
be changed between '10', '20' and '100'. The value displayed last will be adopted.
6.2.20 Forced offset of distance sensor
If the "Forced offset" function is activated, the EPW 400 carries out an offset adjust-
ment for the respective channel automatically every time it is switched on. If this func-
tion is not activated, the EPW 400 is ready to measure as soon as it is switched on.
Tap on the input field next to 'Forced offset' to switch the forced offset on or off.
The last setting displayed will be adopted.
6.2.21 Filter
With the parameter 'Filter' the cutoff frequency of the measuring channel can be set.
Value range: 5 Hz - 1000 Hz