TO HOME
AUTOMATION
SYSTEM
NOTE:
•
Digital I/O must be connected to a dry contact relay.
•
Analog flame and light input through 0 - 10 volt DC
signal scaled as follows:
Low = 1 volt
High = 10 volts
NOTE:
When a signal has been supplied by the home automation system, the fireplace control
will repeat the signal every 2 hours or until a new command has been received.
Fig. #29
Fig. #30
The home automation feature supplied with this fireplace is capable
of controlling the flame and light on/off function with the use of a dry
contact relay common to home automation systems. Furthermore, the
flame and light level may be modulated from high to low using the
0 - 10 volt analog output available on most home automation systems.
Fig #30 shows the wire designations required to connect the fireplace
to a home automation system.
Home Automation
Note: Leave the wall switch on the “Remote” setting when using
home automation.
16
TCWS54_D 281114-44
Summary of Contents for TCWS54 SERIES D
Page 39: ...Fig 65 39 TCWS54_D 281114 44 Wiring Diagram ...
Page 42: ...42 TCWS54_D 281114 44 ...
Page 43: ...43 TCWS54_D 281114 44 ...