Installation, use and maintenance instructions

 

Kerosene and gas oil burners

 

One stage operation  

 

   

  

 

CODE

MODEL

TYPE

 

8099085

SIME MACK 1 EI

515 T3K

8099090

SIME MACK 2 EI

515 T5K

Summary of Contents for MACK 1 EI

Page 1: ...2902764 1 Installation use and maintenance instructions Kerosene and gas oil burners One stage operation CODE MODEL TYPE 8099085 SIME MACK 1 EI 515 T3K 8099090 SIME MACK 2 EI 515 T5K...

Page 2: ...4...

Page 3: ...ixing 3 3 2 Hydraulic systems 4 3 3 Electrical wiring 5 4 WORKING 6 4 1 Combustion adjustment 6 4 2 Nozzles recommended 7 4 3 Maintenance position 7 4 4 Electrodes setting 7 4 5 Air damper adjustment...

Page 4: ...m2 s at 20 C Hi 11 86 kWh kg Electrical supply Single phase 50Hz 230V 10 Motor Run current 0 7A 2850 rpm 298 rad s Capacitor 4 F Ignition transformer Secondary 8 kV 16 mA Pump Kerosene maximum pressur...

Page 5: ...TANDARDS 3 1 BOILER FIXING Put on the flange 1 the screw and two nuts see fig 2 Widen if necessary the insulating gasket holes 5 Fix the flange 1 to the boiler door 4 using screws 2 and if necessary t...

Page 6: ...the return line arrive over the fuel level a non return valve is required This solution however is less safe than previous one due to the possibility of leakage of the valve It is necessary to instal...

Page 7: ...e in compliance with the rules in force in the Country DO NOT EXCHANGE NEUTRAL WITH PHASE WARNING ACCESS TO THE PHOTORESISTANCE See fig 9 The photoresistance is fitted directly into the con trol box u...

Page 8: ...in the table APPROXIMATE ADJUSTMENTS FOR INSTALLATION ON OTHER BOILERS The values shown in the table are measured on a CEN boiler as per EN 267 They refer to 12 5 CO2 at sea level and with kerosene a...

Page 9: ...tion of the air rate is made by adjusting the fixed air damper 3 after loosing the screws 4 When the optimal regulation is reached screw tight the screws 4 to assure a free movement of the mobile air...

Page 10: ...ed technician in conformity with legislation and local standards Maintenance is essential for the reliability of the burner avoiding the excessive consumption of fuel and consequent pollution Before c...

Page 11: ...d personnel FAULTS POSSIBLE CAUSES SOLUTION The green led on the control box is off and the burner does not start Lack of electrical supply Check presence of voltage in the L1 N clamps of the 7 pin pl...

Page 12: ...Fonderie Sime S p A via Garbo 27 37045 Legnago Vr Italy Tel 39 0442 631111 Export Division fax number 39 0442 631293 Sime Service fax number 39 0442 631292...