This fireplace can only be wall terminated using the TCVT. PV1.25 or TCVT.PV7.110 power
vent kit. Please see the instructions supplied with the kit for installation details.
Before installing venting for this unit, the installer should read these instructions to insure
that the proper vent configuration has been selected.
Use only Town and Country Termination kits #:
TCVT.RTA - Roof Termination Kit
Vent system components approved for use with the Town and Country Fireplace are shown
in Fig. #37.
Various combinations of vent runs may be used. Refer to Fig. #
32
for details. For optimum
performance and flame appearance, keep the vent length to a minimum and limit the number
of elbows. Connections between each vent system component must be tightly joined, secured
with sheet metal screws and sealed with provided high temperature self adhesive tape.
VENT SUPPORTS: A minimum of 1 support every 4’ must be used.
CAUTION: UNDER NO CONDITION SHOULD COMBUSTIBLE MATERIAL BE CLOSER
THAN 1 3/4 INCHES FROM ANY PART OF THE VENT PIPE.
This fireplace can only be roof terminated using the TCVT. PVCV power vent kit. Please see
the instructions supplied with the kit for installation details.
18
TCWS54_D 281114-44
Venting
Wall Termination Venting
Roof Termination Venting
Summary of Contents for TCWS54 SERIES D
Page 39: ...Fig 65 39 TCWS54_D 281114 44 Wiring Diagram ...
Page 42: ...42 TCWS54_D 281114 44 ...