12
”
9 5/8”
12
”
74 1/4"
55 1/4"
74 1/4"
22 1/16"
11 5/16"
5/8"
80 5/8"
46 1/4"
33"
114"
74 1/4"
INCLUDING SHEETROCK
MAXIMUM FACING DEPTH
IT IS RECOMMENDED TO USE FULL
SHEETS OF CALCIUM SILICATE
BOARD OR ITS EQUIVALENT AND
FULL LENGTH METAL STUDS TO
FINISH AND FRAME AROUND THE
UNIT.
FOLLOW THE MANUFACTURERS
MOUNTING AND FINISHING IN-
STRUCTIONS CLOSELY.
NON-COMBUSTIBLE
BOARD
NON-COMBUSTIBLE RECESSED
INSTALLATION DETAIL
NON-COMBUSTIBLE BOARD DETAIL
MINIMUM COMBUSTIBLE
FRAMING DIMENSIONS
Fig. #9a
Fig. #9
Fig. #10
Fig. #11
NON-COMBUSTIBLE
MATERIAL MUST EXTEND
12" ABOVE, 9 5/8" TO THE
SIDES AND 12” BELOW THE
FRAMING EDGES.
NON-COMBUSTIBLE
BOARD
NOTE: FIREPLACE SHOULD BE IN ITS FINAL LOCATION BEFORE FRAMING.
STEEL STUDS
NON-COMBUSTIBLE
MASONRY TYPE MATERIAL
NON-COMBUSTIBLE
BOARD
9
TCWS.54CE3 270313-44