The gas control system is located on the right hand side of the firebox behind an access panel and the
decorative firebox panel (if installed). The fireplace is operated by a switch.
The switch (not supplied) is connected to the fireplace by a 14-2 AWG wire, not supplied with the fireplace.
Installation
1. Place the fireplace in the desired location.
2. Remove the window from the fireplace.
3. Remove access panel from right hand side of the firebox (Figure 27).
4. Remove the cover from the electrical box (Figure 28).
5. Run one 110 V. AC switched electrical supplies to the control box and connect to the transformer (Figure
29). The fireplace operates on 24V AC supplied by a transformer rated at 110 volts, 60Hz. See wiring
diagram on page 35 for correct connections on terminal block.
6. Connect the gas supply to the valve (Figure 30).
Honeywell Control Valve Plumbing and Electrical
Access panel
Figure 27: Access panel location.
Electrical box
cover
Figure 28: Electrical box cover.
Gas inlet
Figure 30: Gas inlet.
17
TC36.CODE_271119-40
100003879
Transformer electrical
connections
Figure 29: Transformer connections.