Rating Label Location
NOTE:
The Safety Label is located on a plate found in a slot between the left hand side lintel and the left hand
side window frame. This plate is attached to the lintel with a cable.
FOR OUTDOOR USE ONLY / POUR USAGE EXTÉRIEUR SEULEMENT
Electrical rating:
115v, 60hz, 1.5 A / Note électrique: 115v, 60hz, 1.5 A. This appliance equipped for altitudes 0 - 4500 ft. (0 - 1372 m) / Cet unité est conçu pour
des altitudes variant entre 0 - 4500 pieds (0 - 1372 m). This appliance must be installed in accordance with local codes, if any; if none, follow the current CAN/
CGA-B149 (Canada), or ANSI Z223.1 (USA) Installation Codes. Installer l’appareil selon les codes ou règlements locaux, ou, en l’absence de tels règlements,
selon les codes d’installation CAN/CGA-B149 (Canada), or ANSI Z223.1 (USA) en vigeur. The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with the Canadian Electrical Code, CSA C22.1 or with the National Electrical Code, ANSI/NFPA
70. L’appareil, une fois installé, doit être connecté électriquement à la terre conformément aux codes locaux ou, en l’absence de codes locaux, avec le Code
canadien de l’électricité,CSAC22.1 ou avec le National Electrical Code,ANSI /NFPA70.
WARNING: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. An LP cylinder not connected for
use shall not be stored in the vicinity of this or any other appliance.
AVERTISSEMENT : Ne stockez pas ou utilisez l’essence ou d’autres vapeurs inflammables ou des liquides aux alentours de ceci ou un autre appareil. Un
cylindre LP non connecté pour l’utilisation ne sera pas stocké aux alentours de ceci ou un autre appareil.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY / POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIÉES AVEC
L’APPAREIL
MINIMUM CLEARANCES TO COMBUSTIBLES / CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE
Left and Right side are determined when facing the front of the appliance. / Les côtés droit et gauche se déterminent
en se mettant devant l’appareil et en lui faisant face.
Top, Back and Side Standoffs / Sommet, Arrière et Côté Butée
0 in./ 0 po.
(0 mm)
Sidewall to Appliance / Du mur latéral a l’appareil
4 in./ 4 po.
(102 mm)
Ceiling to Appliance / Plafond a l’appareil
24 in./ 24 po.
(610 mm)
Mantel to Appliance / Du manteau al’appareil
*9 in./ 9 po.
(229 mm)
Maximum Mantel Extension / Allongement maximum du manteau *12 in./ 12 po.
(305 mm)
*See Installation Manual for more detail / Voyez des Directive
de l’Installation pour plus détaux.
Mantel Supports / Supports du manteau
4 in./ 4 po.
(102 mm)
Vent Pipe / Déchargez le Tuyau
1.75 in./ 1.75 po.
(45 mm)
MODEL/
MODELE:
TC36.CODE
SERIES/
SERIE:
A
FOR USE WITH/
NATURAL GAS/
LP GAS/
EN CASE D’EMPLOI AVEC:
DU GAZ NATUREL DU GAZ LP
Minimum supply pressure / Pression minimum d’alimentation:
5.0 in/wc / 5.0 po/c.e.
12.5 in/wc / 12.5 po/c.e.
(For the purpose of input adjustment / dans le but de régler l’alimenation)
(1.25 kPa)
(3.11 kPa)
Maximum supply pressure / Pression maximum d’alimentation:
13.9 in/wc / 13.9 po/c.e. 13.9 in/wc / 13.9 po/c.e.
(3.45 kPa)
(3.45 kPa)
Manifold pressure / Pression de la tuyauterie: Maximum
3.8 in/wc / 3.8 po/c.e.
11.0 in/wc / 11.0 po/c.e.
(.95 kPa)
(2.74 kPa)
Orifice Size / Diametre de l’injectuer:
#30 (3.26 mm)
#45 (2.08 mm)
Input BTU/hr (kW) / Entree BTU/h (kW):
Max.: 47,000 (13.8)
Max.: 47,900 (13.8)
Min.: 35,000 (10.3)
Min.: 35,000 (10.3)
Pacific Energy
Fireplace Products Ltd.
Duncan, British Columbia,
Canada
MADE IN CANADA
FABRIQUE AU CANADA
This Appliance is Equipped For Use With /
Cet Appareil est Équipé Pour Utilise Avec :
NATURAL GAS
GAZ NATUREL
Certified for / Certifié pour Canada and U.S.A.
103013
5050.3601
1-TC36.CODE
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
Refer to the owner’s information manual provided with this appliance. For assistance or additional information, consult a
qualified installer, service agency or the gas supplier.
AVERTISSEMENT: Une installation, un réglage, une modification, une réparation ou un entretien mal effectué peut causer
des dommages matériels ou des blessures. Voir la notice de l’utilisateur qui accompgne l’appareil. Pour de l’aide ou des
renseignements supplémentaires, consultez un installateur, un technicien agréé ou le fournisseur de gaz.
LP-GAS
LP GAZ
Jan.
Feb.
Mar. Apr.
May
June
July
Aug. Sept. Oct.
Nov. Dec.
2013 2014 2015 2016 2017 2018
VENTED OUTDOOR GAS FIREPLACE - NOT FOR USE WITH
SOLID FUEL, FOYER AU GAZ À ÉVACUATION - NE PAS
UTILISER AVEC DU COMBUSTIBLE SOLIDE
ANSI Z21.97-2012 Outdoor Decorative Gas Fireplaces
CSA 2.41-2012 Outdoor Gas Fireplaces
39
TC36.CODE_271119-40
100003879