The lower rear panel is held tight
against the side panels by two "V"
brackets located on the firebox
rear wall. Although the brackets
are adjusted at the factory for the
best fit, some adjustment may be
necessary. Adjust the angle of the
bracket by hand to ensure a snug
fit.
A Firebox Panel Set must be installed for safe operation. Do not use
the fireplace without panels. Unpack and inspect all panels. The panels
need to be installed before the logs are in place.
Caution: The Firebox Panels are very fragile, and should be handled
with care.
1. Remove the Side Panel Retainer located on the underside of the
firebox heat shield (Figure 45). The retainer slips between the lip
of the firebox and the heat shield and is retained in place by two
screws (Figure 46).
(See Porcelain panel instruction manual for specific instructions for these panels) Before proceeding see
burner instructions.
SIDE PANEL
RETAINER
HEAT SHIELD
FIREBOX LIP
Figure 45: Side retainer.
SCREWS
Figure 46: Retainer panel screws location.
29
TC36.CODE_271119-40
100003879
Firebox Panels Installation
REAR LOWER PANEL
ADJUSTABLE “V” BRACKET
Figure 44: Panel brackets.