GENERAL WARNING- AND SAFETY NOTES

•  These installation- and operating instructions form an integral part of the product “gate operator”. They have been spe-

cifically written for professional installers trained and skilled in the trade and should be carefully read in their full length 

before carrying out the installation. They describe the proper installation and operation of the sliding gate operator only, 

not of the overall device “automatic gate”. After the installation this manual has to be handed over to the user.

•   Installation, connection, adjustments, putting into operation, and servicing may only be carried out by trained professionals 

in full accordance with these installation- and operating instructions.

•  Before carrying out works at the gate-system, the power supply has to be turned off.
•  The EU Machine Directive, laws and rules concerning the prevention of accidents, and laws and standards which are in 

force in the EU and in the individual countries have to be strictly followed.

•  The TOUSEK Ges.m.b.H. cannot be held liable for any claims resulting from disregards of the laws and standards in 

force during the installation and operation.

•  The packaging materials (cardboard, plastic, EPS foam parts and filling material etc.) have to be properly disposed of 

in accordance with the applying recycling- and environmental procection laws. They may be hazardous to children and 

therefore have to be stored out of children´s reach.

•  The product is not suitable for installation in explosion-hazardous areas.
•  The product may only be used in accordance with its original purpose, for which it has been exclusively designed, and 

which is described in these installation and operating instructions.  Especially children have to be instructed accordingly. 

The TOUSEK Ges.m.b.H. rejects any liability if the product is used in any way not fully conforming to its original purpose 

as stated herein.

•  Before beginning with the installation the installer has to make sure that all mechanical components of the gate facility, like 

carrier profile/rail, gate frame and panels, guiding elements etc. are sufficiently supportive and resistant for the purpose 

of gate automation.

•  All electrical installations have to be made in full conformity with the applying rules and laws (e.g. using a fault current 

circuit breaker, proper grounding etc.).

•  An all-pole disconnecting main switch with a contact opening-gap of minimum 3 mm has to be foreseen.
•  The electric motor heats up during operation. Therefore the device should only be touched after it has cooled off.
•  After installation the proper function of the gate facility and the safety devices has to be checked!
•  The TOUSEK Ges.m.b.H. rejects any liability for claims resulting from usage of the product in combination with compo

-

nents or devices which do not fully conform to the applying safety laws and rules.

•  Only original spare- and replacement parts may be used for repair of the product.

•  The installer has to inform the user about all aspects of the automatic operation of the complete gate facility, as well as 

about emergency operation. The installer further has to supply to the user all instructions relating to the safe operation 

of the gate facility. The installation and operating instructions also have to be handed over to the user.

•  Please notice that the warranty will not be applicable if the label with the engine number has been removed or 

damaged.

 Maintenance

• 

Maintenance works may only be carried out by qualified personnel.

• 

Check the proper power adjustment once a month.

• 

Check the proper function of the emergency release mechanism periodically.

• 

Check if all mounting screws are securely fastened periodically.

• 

Remove dirt deposits from the operator and gear rack periodically.

•  Lubricate the pivot points of the operator with grease and the push rod with WD40 spray (twice a year or as needed).

•  Maintenance and servicing of the complete gate facility has to be carried out according to the gate builder’s/

installer’s instructions.

This  manual  is  the  sole  property  of  the  TOUSEK  Ges.m.b.H.  and  may  not  be  made  available  to  competitors. All  rights  reserved.  No  part  of  it  may  be  reproduced  without  our  prior 

written  permission.  We  will  not  accept  liability  for  any  claims  resulting  from  misprints  or  errors.  This  edition  of  the  manual  replaces  all  earlier  publications  of  the  same.

Summary of Contents for SLIM C Series

Page 1: ...Installation and Operating Instructions Swing gate operator SLIM S C...

Page 2: ...te frame and panels guiding elements etc are sufficiently supportive and resistant for the purpose of gate automation All electrical installations have to be made in full conformity with the applying...

Page 3: ...uarantee a reliable locking of the gate wing in its closed position The operators SLIM SLR and SLIM CLR are additionally equipped with integrated limit switches Technical specifications Swing gate ope...

Page 4: ...es both in the open EO and closed EG gate positions If this is not the case such stopping devices have to be installed or the Tousek piston rod stroke limiting device has to be used Note The operators...

Page 5: ...ts A and B please mount the rear mounting part 2 at this position on the gate column wall Installation of the front mounting part Connect the front mounting part 1 to the gate leaf keeping the distanc...

Page 6: ...exactly on the circular nose of the push rod and tighten the hexagon socket screw Now insert the clamping piece K in the front mounting part 1 and insert the cylindric bolt Z1 and the cover D from abo...

Page 7: ...e underside of the operator by moving them laterally For adjustment please see manual of control For moving the limit switches you have to unfix the latching at first internal limit switches of SLIM S...

Page 8: ...please follow the below steps Open the hexagon socket screw K1 so far that you can open the clamping piece a bit and move out the push rod Now push rod and gate are no longer connected and the gate c...

Page 9: ...ent prevention rules and laws as well as apply ing EU and national standards in force at the time of installation and operation of the gate facility The Tousek Ges m b H cannot be held responsible for...

Page 10: ...8 5 8 5 40 50 32 40 80 73 755 395 SLIM SLR CLR 330 1105 40 40 4 4 7 7 17 SLIM SR CR 337 rear mounting part front mounting part dimensions in mm 10 Dimensioned drawing Swing gate operator SLIM S C We...

Page 11: ...it in electronic form and within a reasonable time to the market surveillance authorities in response to a duly substantiated request TOUSEK Ges m b H A1230 Wien Zetschegasse 1 sterreich is authorize...

Page 12: ...wicka 67 Tel 48 32 738 53 65 Fax 48 32 738 53 66 info tousek pl Tousek s r o Czech Republic CZ 252 61 Jene u Prahy Pr myslov 499 Tel 420 777 751 730 info tousek cz We reserve the right to change dimen...

Reviews: