Note
• On larger gate columns and inside swinging gate leafs
a recess according to the illustration below has to be
made. This will help you keeping the distances A, B.
•
Note:
The recess in the gate column has to be big
enough to make sure that the electrical supply cable of
the operator will not be buckled.
75
50
ca.50
Mounting measures with different swing gate installations
inside swinging gate wing
(Center of rotation in line with center axis of gate wing)
inside swinging gate wing
(Center of rotation not in line with center axis of gate wing)
Special case - outside swinging gate wing
Installation of the rear mounting part
• After having determined the pivoting point of the operator with regard to the measurements A and B please mount the rear
mounting part
(2)
at this position on the gate column (wall).
Installation of the front mounting part
• Connect the front mounting part
(1)
to the gate leaf, keeping the
distance C.
Please make sure that the gate is fully
closed and that the operator will be mounted horizontally.
• On thin-walled or wood-panel gate leafs the connector bracket must not be mounted directly on the gate leafe.
In these cases a flat steel plate must be installed to support the connector bracket.
Installation on larger gate columns
Important
•
The operator piston rod must not travel out its whole length (at least 5 mm have to remain)! Thus the travel of
the gate wing has to be limited by floor stoppers, or the Tousek piston rod stroke limiting device has to be used.
A
B
C
INSIDE
INSIDE
OUTSIDE
A
B
C
A
B
C
corner plate
A
B
C
INSIDE
Note: In order to increase the strength of the connections we