tousek
/ E_SLIM-SR-CR_42000904 / 21. 11. 2017
- 9 -
NOTE
concerning cab
le laying
The electric cables have to
be laid in insulating
sleeves
which
are
suitable
for
underground
usage.
230
V
cables
and
control
lines
have
to
be
laid
in
separate sleeves.
Only
double-insu
lated
cables,
which
are
suitable
for
underground
usage
(e.g.
E-YY
-J)
may
be
used.
In case that special
regulations
require
another
type of
cable, cables according to
these regula
-
tions have to be used.
SAFETY
NOTE
Please be aware that the beside picture is only
a
symbolic
sample illustration
of
a gate
facility
and
may
therefore not
show all
safety devices required for your
specific application.
To
achieve an optimum
safety level at your
gate facil
-
ity
, please make sure that all
safety components
and
accessories which
- according
to
the
applying
safety
rules and laws - are required in
your particular case
(e.
g.
p
ho
to
cel
ls,
in
du
cti
on
lo
op
s,
sen
si
ng
ed
ges,
si
gn
al
lamps,
traffic
lights
, mains-
and
emergency
power
off
switches etc.) are properly installed,
operated, and
serviced. In
this context please follow
the EU Machine Directive,
accident prevention
rules and
laws,
as well
as apply
-
ing
EU- and
nation
al
standards in
force at
the
time of
installation and operation of the gate facility
.
The
Tousek
Ges.m.b.H.
cannot
be
held
responsible
for
any consequences resulting
from
disregard of
applying
standards and laws during
installation
or
operation of the gate facility
.
The
0,75mm
2
control
lines
are
shown
witho
ut
ground
lead.
In
order to
facilitate connections
we
recommend
using
flexible
wires
and
not
using thicker wires for the control lines.
9.
Cable plan
Swing gate operator SLIM S/C
1
operator
Tousek SLIM
1a
connection box
2
electronic logic control
(optional with integrated radio
receiver)
3
external antenna (for increas
ed range)
4
signa
l light
5
external fotocell
6
internal fotocell
(
T:
transmitter
,
R:
receiver)
7
main power switch and fuse 1
2A
Note:
An all-pole disconnectin
g main switch with a contact
open
ing-gap of minimum 3 m
m has to be foreseen.
8
pushbutton momentary conta
ct switch
9
key-operated momentary con
tact switch
10
safety sensing edges
11
hinge
d lockiing bar
12
electric lock
13
floor stops
coaxial cable
3
4
3 x 1
2
2 x 1,5
2
2 x 1,5
2
2 x 0,75
2
4 x 0,75
2
2 x 0,75
2
2 x 0,75
2
2 x 0,75
2
4 x 0,75
2
2 x 0,75
2
4 x 0,75
2
3 x 1,5
2
10
10
5R
5T
9
6T
6R
8
7
2
12
11
13
13
13
13
2 x 1
2
1a
1a
1
1