5. Putting into operation
REX Force
important: preparation works
• All electrical installations (control panels, safety devices ...) have to be made in full conformity with the applying rules
and laws.
Attention: if no stop switch is connected then the terminals 30/31 have to be bridged.
•
The mechanical limits have to be placed so that contact edges are not triggered, as this would lead to an
error message.
• For automatic positioning: Unlock emergency release of operator and set gate to half-opened position.
Then lock the operator again.
• Switch on the operator (correct connection necessary).
•
Important:
Putting into operation in Impulse mode (standard setting) and not in dead man mode.
• During initial operation the choice of language is made first, afterwards the choice of
Gate positioning
: „
auto-
matic
“ or „
manual
“ and finally in the „
Basic settings
” the adjustment of the most important operator settings. After
the successfull system test the detection of limit positions of gate is performed automatically or manually.
•
After giving the impulse to automatically program the end positions, no other impulse must be given. Also the
safety devices mustn´t be triggered. This would lead to an interruption of the programming process.
BASIC SETTINGS
•
For setting the most important adjustments for initial operation of motor.
•
Can be selected during initial operation (hence when restoring the factory setting).
•
All safety devices are activated when leaving factory
(
page 20).
•
The next programming adjustments are made in THE MAIN SETTINGS MENU
(
page 19).
factory settings
t
PHC = photocell
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
PHC inside
3
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
PHC inside
active
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
PHC indside
not active
change? YES
confirm
inner photocell
3
4
inner photocell
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
language
Deutsch
2
1
scroll
confirm
confirm
LANGUAGE SELECTION and POSITIONIG
•
Can be selected during initial operation (hence after reset to factory settings).
• Language selection can be also c
hosen by pressing the ESC button
(
)
for 5s
, from any position in menu.
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
basic settings
confirm
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
positioning
automatic
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
positioning
manual
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
postitioning
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
Vx.x
2
confirm
3
Danger: Before commissioning check again the mechanical door construction and the gate limit stops