tousek
/ EN_REX-Force_01 / 25. 03. 2020
- 15 -
–
ESC
ENTER
+
FE
textdisplay
Z1
ZM
TA
D
E
VE
F1
T1
B
J1/2
1 2
1 gate leaf
1 2
2 gate leaves
3.2 Control board ST REX and ST REX smart
REX Force
Elements of the main control board ST REX
(Z1)
Terminal blocks ST REX
(B)
Bus Terminals (88/89)
Connection with optional traffic light control STA 11
(TA)
additional pulse button (corresponding to
Z1
: Kl 30/32)
(D)
Display connection (with programming b, -, ESC,
ENTER) or TSI connection (optional service interface)
(E)
Connection socket for optional electric lock
module/motor bolt module
(VE)
230Va.c. for magnetic clamp module
(FE)
Slot for optional radio receiver
(ZM)
Slot for optional additional module
(Courtyard / control light or gate status display)
(F1)
Fuse 4A T
(T1)
transformer
(J1/2)
Jumper for defining the number of leaves
F2
T2
Z2
JF
S
L
TSI
Components of the motor control unit ST REX smart
(Z2)
Terminal blocks ST REX smart
(S)
Connector for sensor
(TSI)
TSI connector (optional service interface)
(T2)
Transformer
(F2)
Fuse 2A T
(L)
LED: lights up when connected to ST REX
(JF)
Jumper: defines LEFT / RIGHT gate leaf
Connection ST REX / ST REX smart
The ST REX is connected to the ST REX smart motor
control unit by means of a bus cable, via the terminals
84/85/86!
LEFT
RIGHT
left INSIDE right