tousek
/ EN_GTZ-Digital_07 / 10. 10. 2019
- 21 -
Level 7
maintenance and service
Level 7
Menu 1
Cycle counter
Six-digit display of door operations up to 999999. Numbers listed in a row until „point“ appears, then repetition.
Level 7
Menu 2
Maintenance counter
five-digit display of the left door movements until next maintenance. Numbers listed in a row until „point“ appears, then repetition.
Level 7
Menu 3
Maintenance schedule
Setting the number of the gate movements from which the message „maintenance necessary“ will be displayed.
1
OFF
9
8.000 door movements
2
100 door movements
10
9.000 door movements
3
500 door movements
11
10.000 door movements
4
1.000 door movements
12
15.000 door movements
5
4.000 door movements
13
20.000 door movements
6
5.000 door movements
14
30.000 door movements
7
6.000 door movements
15
40.000 door movements
8
7.000 door movements
16
50.000 door movements
7. Level
Menu 8
Reset service and maintenance
Reset of the error memory for service, diagnosis and maintenance
.
1
no RESET
2
RESET error memory
level 7
Menu 9
Error display
Display of the current error message (max. 16 error messages possible).
Display the previous errors /
Browse through the error list
Browse through the error list