Level 5
Special functions
Level 5
Menu 1
programmable impulse input (terminal 1/2)
1
Impulse (normally open contact)
in automatic mode only opening command,
When opening:
No function
During the pause time: Restart the pause time
When closing :
Reversing till door is open
5
OPEN impulse (normally open contact)
during the movement: no function
if automatic closing is activated: pause time extension and
reverse when closing
2
closing prevention (normally open contact)
6
earlier closing possible by pressing the impulse button or
transmitter > 2 seconds
3
Stops and reverses (only direction door CLOSED -
normally close contact)
7
impulse (normally open contact only) with permanent
24V DC / max. 50mA power supply
4
Stops and reverses (only direction door CLOSED -
normally open contact)
Level 5
Menu 4
lighting duration
= 3.0 (180 seconds)
2 – 250 seconds.
Level 5
Menu 5
Optional function
= 1 (do not change)
Factory settings = 1 - do not change!
Level 5
Menu 7
Optional function
= 1 (do not change)
Factory settings = 1 - do not change!