9 EN
TANK
COOLING
PROCEDURE
In
order
for
this
procedure,
you
must
have
a
minimum
of
5
lbs.(2.3kg)
of
liquid
refrigerant
in
the
storage
tank.
1.
Connect
the
hoses
as
shown.
2.
Turn
the
MODE
valve
to
the
Recover
position.
3.
Open
the
Vapor
and
Liquid
valve
of
the
storage
tank.
4.
Power
on,
and
start
the
compressor.
5.
Open
the
INPUT
valve
and
OUTPUT
valve
of
the
machine.
6.
Throttle
the
OUTPUT
valve
of
the
machine
so
that
the
output
pressure
is
100psi
greater
than
the
input
pressure,
but
never
more
than
300psi.
7.
Run
until
tank
is
cold.