7 EN
SELF
‐
PURGE
PROCEDURE
Procedure
for
purging
remaining
refrigerant
from
this
machine.
1.
Close
the
ports
of
the
system
being
serviced
that
are
connected
to
the
input
port
of
the
machine.
2.
Turn
off
the
recovery
machine.
3.
Turn
the
Input
valve
to
the
PURGE
position.
4.
Turn
the
MODE
valve
to
the
PURGE
position.
5.
Restart
the
machine.
6.
Run
until
desired
vacuum
is
achieved.
7.
Close
the
ports
on
the
recovery
tank
and
the
machine.
8.
Turn
the
machine
off.
9.
Return
the
MODE
valve
to
the
RECOVER
position.
10.
Disconnect
and
store
all
hoses
and
dry
filter
Summary of Contents for TTL-RECO250S