3 EN
system.
Use
two
high
acid
capacity
filters,
in
series.
When
you
have
finished
recovering
from
the
system,
flush
the
recovery
machine
with
a
small
amount
of
clean
refrigerant
and
refrigerant
oil
to
purge
off
any
foreign
substances
left
in
the
machine.
16.
This
recovery
machine
has
a
Pressure
Shut
Off
Switch.
If
the
pressure
insi
de
the
system
should
go
above
38bars,
the
system
will
automatically
shut
itself
off.
The
shut
off
switch
must
be
manually
reset.
17.
If
the
tank
pressure
exceeds
20.7bar,
use
the
TANK
COOLING
PROCEDURE
to
reduce
the
tank
pressure.
18.
To
maximiz
e
recovery
rates,
use
the
shortest
possible
length
of
3/
8”
or
larger
hose.
A
hose
no
longer
than
0.9meter
is
recommended
19.
When
recovering
large
amounts
of
liquid,
use
the
LIQUID
PUSH
/PULL
PROCEDURE.
20.
After
recovering,
make
sure
there's
no
refrigerant
left
in
the
machine.
Read
the
SELF
‐
PURGING
PROCEDURE
carefully.
Liquid
refrigerant
remained
may
be
expanded
and
destroy
the
components.
21.
If
this
recovery
machine
is
to
be
stored
or
not
used
for
any
length
of
time,
we
recommend
that
it
be
completely
evacuated
of
any
residual
refrigerant
and
purged
with
dry
nitrogen.
22.
To
reduce
the
risk
of
injury,
care
should
be
taken
when
moving
this
machine.
Summary of Contents for TTL-RECO250S
Page 1: ...USERMANUAL EN TTL RECO250S REFRIGERANT RECOVERY UNIT ...
Page 2: ......
Page 14: ...12 EN TROUBLESHOOTING ...
Page 15: ...13 EN WIRING DIAGRAM ...
Page 16: ...14 EN PARTS DIAGRAM TTL RECO250S ...
Page 17: ...ISTRUZIONID USO IT TTL RECO250S UNITA DI RECUPERO REFRIGERANTE ...
Page 29: ...12 IT RISOLUZIONE PROBLEMI ...
Page 30: ...13 IT SCHEMA ELETTRICO ...
Page 31: ...14 IT VISTA ESPLOSA TTL RECO250S ...
Page 32: ...GEBRUIKERSHANDLEIDING DE TTL RECO250S AFZUIGUNIT KOUDEMIDDELEN ...
Page 44: ...12 DE STÖRUNGSSUCHE ...
Page 45: ...13 DE SCHALTPLAN ...
Page 47: ...GEBRUIKERSHANDLEIDING NL TTL RECO250S AFZUIGU NIT KOUDEMIDDELEN ...
Page 59: ...12 NL PROBLEMEN OPLOSSEN ...
Page 60: ...13 NL ELEKTRISCHE SCHEMA S ...