32
RE V. 1.0-12 /16
5.3 INSTALLATION
5.3.1 i
nstallation
area
features
Do not use the device in a dirty, wet or very humid place.
r
oom
requirements
For the normal-use of the machine, including the operations of loading and unloading, it is necessary to have a space directly proportional
and appropriate to the size of the objects to be machined. The installation site must have the floor horizontal, flat, stable, non-resilient,
and near a power outlet.
a
tmosPheriCal
agents
ProteCtion
The machine must be placed in a covered and protected from direct contact with atmospheric agents (enclosed).
w
orking
surfaCe
Prepare the horizontal supporting surface on which to place the machine knowing the mass of the machine. Also take into consideration
ancillary equipment (tables, etc.).
l
ighting
To carry out safe working and maintenance of the machine requires good lighting industrial grade for machining of medium accuracy
(approximately 300-600 lux).
e
nvironmental
features
Allowable Temperature: from 15 °C to 40 °C. Humidity: 10% to 90% (non-condensing).
5.3.2 e
leCtriCal
features
Must be in place near the machine.
•
Turn off the power to the outlet or junction box where you would like to connect the machine
•
Make sure the connection of the grounding is operative and functional
•
Verify that the power supply line is adapted to the power of the machine
•
Check the switch on the power line carrying power to the machine and that its power interruption is suitable for a hypothetical
situation of failure
•
Connect the power cable to a power characteristics suitable for the plug provided with the cable
•
For proper electrical connection the machine must be connected to the phase to neutral and the ground conductor
•
Turn the power to the electrical line carrying power to the machine
The power cable of the electrical energy must be adequately protected and should not cause hindrance to the operator.
This machine is equipped with automatic switch in case of overload of the motor (it is positioned close to the ignition switch) in order to
allow the proper functioning of the engine.
In case of overload, the circuit breaker is activated by interrupting the power supply to the machine. After a minute, problem solved, press
the circuit breaker and the motor will start again.
5.3.3 t
est
Before operating, ordinary and continuing use of the machine, check the perfect functioning general, performing at least some test
application.
If you feel vibrations or noises particular during operation, stop the machine immediately and investigate the cause.
Ch a P t ER 5: iNsta l l at iON