E6582175
K-14
11
Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
0349
Acceleration/decele
ration suspend
function
-
1/1
0:Disabled
1:Parameter setting
2:Terminal input
0
6.23
0350
Acceleration
suspend frequency
Hz
0.1/0.01
0.0-
0.0
0351
Acceleration
suspend time
s
0.1/0.1
0.0-10.0
0.0
0352
Deceleration
suspend frequency
Hz
0.1/0.01
0.0-
0.0
0353
Deceleration
suspend time
s
0.1/0.1
0.0-10.0
0.0
0359
PID control
waiting time
s
1/1
0-2400
0
6.24
0360
PID control
-
-
0: Disabled
1: Process type PID control
2: Speed type PID control
0
0361
Delay filter
s
0.1/0.1
0.0-25.0
0.1
0362
Proportional gain
-
0.01/0.01
0.01-100.0
0.30
0363
Integral gain
s
-1
0.01/0.01
0.01-100.0
0.20
0366
Differential gain
s
0.01/0.01
0.00-2.55
0.00
0367
Upper limit of set
value
Hz
0.1/0.01
0.0-
*1
0368
Lower limit of set
value
Hz
0.1/0.01
0.0-
0.0
0369
PID control
feedback signal
selection
-
-
0: Disabled
1: Terminal VIA
2: Terminal VIB
3: Terminal VIC
4 to 6: -
0
0372
Process increasing
rate (speed type
PID control)
s
0.1/0.1
0.1-600.0
10.0
0373
Process decreasing
rate (speed type
PID control)
s
0.1/0.1
0.1-600.0
10.0
0375
Factory specific
coefficient 3E
-
-
-
-
* 3
0376
Factory specific
coefficient 3F
-
-
-
-
0378
Number of pulse
train input
pps
1/1
10-500
25
6.10.5
0380
PID forward/reverse
characteristics
selection
-
-
0: Forward
1: Reverse
0
6.24
0382
Hit and stop
control
-
-
0: Disabled
1: Enabled
2: -
0
6.22.2
0383
Hit and stop
control frequency
Hz
0.1/0.01
0.1-30.0
5.0
*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.