E6582175
F-129
6
■ Password examination method
(1) When
f738
or
f739
are read out and the value is
9999
, a password has already been set.
Password has to be removed in order to change parameters.
(2) Enter a the number (
1
to
9998
) registered to
f739
when the password was set for
f738
.
(3) If the password matches,
pass
blinks on the display and the password is removed.
(4) If the password is incorrect,
fail
blinks on the display and
f739
is displayed again.
(5) When the password is removed, the setting for parameter
f700
can be changed.
(6) By setting parameter
f700
=
0
, the all parameter settings can be changed.
Note 7: Entry of
setting is possible up to 3 times. Please note it is impossible to set, if you enter the
wrong number for 3 times. Number of times is reset after power is off.
2) Resetting method of prohibition settings:
f700
and
f737
■ Resetting method
(1) Canceling the
f700
prohibition setting
The setting of only parameter
f700
can be changed at any time, even if it is set to
1
.
(2) Canceling he
f737
prohibition setting
When this parameter is set to
1
(key operation prohibited), press and hold down the key for
5 seconds or more. The message
und
appears and this setting is canceled temporarily to enable key
operation. To cancel this setting permanently, change the setting of
f737
directly
3) Setup method when parameter protection is necessary
■ Prohibit changing parameters settings and reading parameters from logic input
Set "Parameter editing prohibition" or "Parameter reading/editing prohibition" for an input terminal.
Activating the "Parameter editing prohibited" function prevents changes to parameters.
Activating the "Parameter reading/editing prohibition" function prevents reads and writes to parameters.
The following table shows an example of setting input terminal S1 and S2.
Title
Function
Adjustment range
Setting
f114
Input terminal selection 4A
(S1)
0-203
200: PWP
(Parameter editing prohibition)
f115
Input terminal selection 5
(S2)
0-203
202: PRWP
(Parameter reading prohibition)
Setting value 201, 203 are reverse signal.
ENT
Summary of Contents for TOSVERT VF-S15 series
Page 394: ......