J-
13
[24] Torque limit
Vector control
Title
Communi
cation No
Function
Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0440
Selection of power running torque limit #1 1 :VI/II, 2: RR, 3: RX, 4: RX2, 5:
−
5
Enabled
●
/
●
●
/
●
−
/
●
●
6.22
0441
Power running torque limit #1 0
〜
249.9 [%], 250: Invalid
0.1/0.01
250.0
Enabled
●
/
●
●
/
●
−
/
●
●
6.22
0442
Selection of regenerative torque limit #1 1 :VI/II, 2: RR, 3: RX, 4: RX2, 5:
−
5
Enabled
●
/
●
●
/
●
−
/
●
●
6.22
0443
Regenerative torque limit #1
0
〜
249.9 [%], 250: Invalid
0.1/0.01
250.0
Enabled
●
/
●
●
/
●
−
/
●
●
6.22
0444
Power running torque limit #2 0
〜
249.9 [%], 250: Invalid
0.1/0.01
250.0
Enabled
●
/
●
●
/
●
−
/
●
●
6.22
0445
Regenerative torque limit #2
0
〜
249.9 [%], 250: Invalid
0.1/0.01
250.0
Enabled
●
/
●
●
/
●
−
/
●
●
6.22
0446
Power running torque limit #3 0
〜
249.9 [%], 250: Invalid
0.1/0.01
250.0
Enabled
●
/
●
●
/
●
−
/
●
●
6.22
0447
Regenerative torque limit #3
0
〜
249.9 [%], 250: Invalid
0.1/0.01
250.0
Enabled
●
/
●
●
/
●
−
/
●
●
6.22
0448
Power running torque limit #4 0
〜
249.9 [%], 250: Invalid
0.1/0.01
250.0
Enabled
●
/
●
●
/
●
−
/
●
●
6.22
0449
Regenerative torque limit #4
0
〜
249.9 [%], 250: Invalid
0.1/0.01
250.0
Enabled
●
/
●
●
/
●
−
/
●
●
6.22
0450
Torque limit mode (polarity)
0: Power-running/regenerative torque limit
1: Positive/negative torque limit
−
0
Disabled
●
/
●
●
/
●
−
/
●
●
6.22
0451
Torque limit mode
0: Standard, 1: without speed cooperation
−
0
Enabled
●
/
●
−
−
●
※
0452
Continuous stall trip detection
time during power running
0.0
〜
1.0 [s]
0.1/0.01
0.0
Enabled
●/●
−
−
●
−
0453
Stall prevention during regeneration
0: Stall
1: Stall is prevented
−
0
Enabled
●/●
−
−
●
−
[25] Speed/torque reference gain/bias setup #2(1/2)
Vector control
Title
Communi
cation No
Function
Adjustment range
Min. unit (panel/
communication)
Default
setting
Write during
running
Speed
control
Torque
control
Position
control
V/f
Constant
Reference
section
0454
Current differential gain
0.00
〜
327.6
0.01/0.01
123.0
Enabled
●/−
−
―
●
−
0455
High-speed magnetic field
control gain
1.64
〜
327.6
0.01/0.01
16.38
Enabled
●/●
●/●
―/●
●
−
0456
High-speed magnetic field
rate-of-change limitation
gain
1.64
〜
327.6
0.01/0.01
163.8
Enabled
●/●
●/●
―/●
●
−
0470
VI/II reference bias
0
〜
255
1/1
99
Enabled
●/●
●/●
―/●
●
−
0471
VI/II reference gain
0
〜
255
1/1
142
Enabled
●/●
●/●
―/●
●
−
0472
RR reference bias
0
〜
255
1/1
100
Enabled
●/●
●/●
―/●
●
−
0473
RR reference gain
0
〜
255
1/1
164
Enabled
●/●
●/●
―/●
●
−
0474
RX reference bias
0
〜
255
1/1
67
Enabled
●/●
●/●
―/●
●
−
0475
RX reference gain
0
〜
255
1/1
128
Enabled
●/●
●/●
―/●
●
−
0476
RX2 reference bias
0
〜
255
1/1
67
Enabled
●/●
●/●
―/●
●
−
0477
RX2 reference gain
0
〜
255
1/1
128
Enabled
●/●
●/●
―/●
●
−
0480
Exciting strengthening coefficient 0
〜
255
1/1
64
Enabled
●/―
●/―
―
―
−
0481
Over-excitation cooperation
0: Enabled, 1: Applied by
setting
−
0
Enabled
●/―
●/―
―
―
−
0482
Modulation rate control
margin (current control)
80.0
〜
300.0 [%]
0.1/0.01
90.0
Enabled
●/●
●/●
―/●
−
−
Sensorless vector/vector with sensor (
●
valid,
−
:invalid)