TDP-MT8 Service Guide
56
Lamp Connector Retainer
1.
Lift the lamp connector through the rectangular slot in the lamp connector retainer.
2.
Remove the lamp connector retainer.
Assembly Notes
♦
To install the safety switch, orient it so that the lever actuator faces away from the mounting tab on
the chassis. The curved portion of the lever actuator fits into the slot in the bottom case near the lamp
cavity. A tab on the lamp door fits through the slot to close the safety switch when the lamp door is in
place.
♦
Torque the two M2x8 Torx screws to 6 in/lbs. (.68 Nm).
♦
Orient the thermal switch on lamp connector retainer so that the screw hole on the switch aligns with
the hole in the retainer. The white lettering on the switch should face up.
♦
Torque the M3x6 Torx Plastite screw to 3 in/lbs (.34 Nm).
♦
After you install the safety switch, route the cable through the eye on the chassis. Connect the cable
to J3 on the power supply.