3.
Fully extend the elevator shaft. Then use the small screwdriver to gently pry the stop on the
elevator housing away from the elevator shaft. This allows the elevator shaft to pass through the
housing and out of the bottom case.
CAUTION
Take care when prying the stop. It can easily break. If a stop breaks, the bottom case
must be replaced.
4.
Pull the elevator shaft out from the bottom side of the projector.
Remove the Elevator Spring and Actuator
1.
Remove the elevator shaft, then remove the:
Optical engine (see page 22)
2.
Use a small screwdriver or angled pick to remove the elevator spring from the slot in the elevator
actuator.