TDP-MT8 Service Guide
58
4.
Unplug the lamp blower contact ECA cable and the speaker cable from their connectors on the
controller ECA. Then disconnect the keypad cable from the ZIF connector on the controller ECA.
5.
If you are going to replace the top case with a new one, remove the top case parts (see page 59)
and save them for use with the replacement top case.
Assembly Notes
♦
If you're replacing the top case with a new one, install the top case parts (see page 59) that you
removed from the old one.
♦
Adhere a new nameplate to the top case in the recess near the handle.
♦
Connect the keypad lamp blower contact ECA cable, the speaker cable and the keypad cable.
♦
Make sure that the top case fits flush over the bottom case.
♦
Torque the two black M3x8 Torx screws to 6 in.-lbs. (.678 Nm).
Summary of Contents for TDP-MT8
Page 1: ...TDP MT8 FILE NO 330 200209 TDP MT8 DOCUMENT CREATED IN JAPAN Nov 2002 ...
Page 84: ...TDP MT8 Service Guide 84 Block Diagram ...
Page 90: ...TDP MT8 Service Guide 90 ...
Page 92: ...TDP MT8 Service Guide 92 Parts Lists Component Parts Exploded View ...
Page 93: ...TDP MT8 Service Guide 93 Case Parts Exploded View ...
Page 97: ...TOSHIBA CORPORATION 1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...