TDP-MT8 Service Guide
72
Power Diagnostics, Error Codes
3 flashes
The projector detected an
internal error and shutdown
the lamp.
Diagnose lamp shutdown.
(pag 74)
Interpret
red LED
behavior
Flashing
Is the LED steady or
flashing?
Steady
An internal error occurred that
the projector cannot identify.
Diagnose the error.
(page 72)
What is the
flashing pattern?
Red LED
flashes have
2-second intervals
between series of
flashes. For example,
the LED may flash 4
times, the pause for 2
seconds, the flash 4
times again.
5 flashes
The projector detects high
internal temperature.
Diagnose thermal problems.
(pag 75)
On
Off
4 flashes
A fan failed.
Check the fans.
(page 26)
On
Off
On
Off
2 flashes
The lamp timer registers
lamp use of 2000 hours
or more.
Replace the lamp.
(page 37)
On
Off
1 flash
The lamp failed to strike after
five attempts.
Diagnose lamp strike failure.
(page 73)
On
Off
Summary of Contents for TDP-MT8
Page 1: ...TDP MT8 FILE NO 330 200209 TDP MT8 DOCUMENT CREATED IN JAPAN Nov 2002 ...
Page 84: ...TDP MT8 Service Guide 84 Block Diagram ...
Page 90: ...TDP MT8 Service Guide 90 ...
Page 92: ...TDP MT8 Service Guide 92 Parts Lists Component Parts Exploded View ...
Page 93: ...TDP MT8 Service Guide 93 Case Parts Exploded View ...
Page 97: ...TOSHIBA CORPORATION 1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...