Clocks
The ImageProcessor requires memory (MCLK) and display (DCLK) clocks. The MCLK runs
the internal memory system and the on-chip CPU. The DCLK is used to generate the output display
timing. These clocks are typically generated by an internal PLL-based clock generator circuit. An
external crystal is required. Because the ImageProcessor is a CMOS device, the power it consumes
is proportional to the speed of the input clocks. The clock inputs to the ImageProcessor are not 5V
tolerant. In addition, during DPMS power down modes, the clocks should be slowed down or
stopped. Refer to
Application Note # 15, Display Power Management (DPMS)
.
Display Interface
TTL
Connect TTL compatible displays directly to the ImageProcessor display port. The display port
has high current drivers to drive long traces or short cables. Use series termination near the
ImageProcessor for good EMI performance. If long cabling is required, buffer the DPort signals with
a high drive buffer.
Fan Control Interface
The Fan Control IC contains the precise digital thermometer, fan controllers, and a system-reset
circuit. The thermometer reports the temperature of 2 remote sensors and its own package. The
remote sensors are diode-connected transistors typically a low-cost, easily mounted 2N3904 NPN
type that replace conventional thermistors or thermocouples. Remote accuracy is ±5°C for multiple
transistor manufacturers, with no calibration needed. The remote channel can also measure the die
temperature of other ICs, such as microprocessors, that contain an on-chip, diode-connected
transistor.
Summary of Contents for TDP-D1
Page 8: ...7 Lamp box Input module ...
Page 9: ...Chapter 2 Assy and Disassy drawing 8 ...
Page 10: ...9 ...
Page 11: ...10 ...
Page 12: ...11 ...
Page 13: ...12 ...
Page 14: ...13 ...
Page 15: ...14 ...
Page 16: ...15 ...
Page 23: ...22 3 Remove 2 cables 4 Lift the rear bezel ...
Page 27: ...26 9 Remove 4 screws 10 Saparate the Input board from the PC board interface ...
Page 29: ...28 2 Lift the upper power board 3 Remove 2 cables 4 Remove 4 screws for ballast ...
Page 41: ...40 Chapter 5 Trouble shooting guide ...
Page 42: ...41 ...
Page 47: ...46 4 Power Supply Trouble Shooting Guide PFC BOARD DX850 DC DC BOARD ...
Page 48: ...47 5 DMD Block Trouble Shooting Guide ...
Page 49: ...48 ...
Page 50: ...49 ...
Page 52: ...51 Step 4 Setting COM Port Baud Rate ...
Page 54: ...53 Step 6 Start download firmware ...
Page 55: ...54 Step 7 Download finished Step 8 Turn off the power switch ...
Page 110: ...109 Figure 1 Major Blemish Two Zone Screen Non Critical Zone Critical Zone center 25 ...