7.
状態モニタモードでの操作
9-1
Item
Specifications
Model number
RKP004Z
Applicable model
VF-AS1 inverter unit
Communication
setting
Baud rate: 19200 bps
Communication type: 2-wire RS485
Use environments
Indoors, an altitude of 3000m or less, where the product will
not be exposed to direct sunlight, corrosive or explosive
gases, vapor, coarse particulates including dust, and where
there is no grinding fluid or grinding oil nearby
Ambient temperature
-10 to +60°C
Storage temperature
-25 to +65°C
Relative humidity
20 to 93
%
(no condensation and absence of vapor)
Vibration
5.9m/s
2
(0.6G) or less (10 to 55Hz) (compliant with JIS C
60068-2-6)
Cooling method
Self-cooling
■
Outside dimensions (unit: mm)
98
26
107
9. Specifications