22
1-1-5. Slim Duct
<Single type>
Model
Indoor unit
RAV-RM
561SDT*
Outdoor unit
RAV-GP
561ATW*
Cooling capacity
(kW)
5.0
Heating capacity
(kW)
5.6
Power supply
220 - 240 V ~, 50 Hz
(Power supply from outdoor unit)
Electrical
characteristics
Cooling
Running current
(A)
7.57-6.94
Power consumption
(kW)
1.56
Power factor
(%)
93
EER
3.21
SEER
5.77
Energy efficiency class (Lot10)
A+
Heating
Running current
(A)
7.81-7.15
Power consumption
(kW)
1.58
Power factor
(%)
93
COP
3.54
SCOP
4.20
Energy efficiency class (Lot10)
A+
Maximum current
(A)
13.1
Indoor unit
Fan unit
Fan
Centrifugal fan
Standard air flow (H/M+/M/L+/L)
(m³/min)
13.0/-/11.3/-/9.7
Motor
(W)
60
Sound pressure level
(H/M+/M/L+/L)
(dB(A))
45/-/40/-/36
Sound power level
(H/M+/M/L+/L)
(dB(A))
55/-/53/-/48
Outdoor unit
Length of refrigerant
pipe
Max. total length
(m)
50
Min. length
(m)
3
Height
difference
Outdoor lower
(m)
30
Outdoor high
(m)
30
Fan unit
Fan
Propeller fan
Standard air flow high
(m³/min)
37.5
Motor
(W)
43
Connecting pipe
Outdoor unit-
Pipe branch
Gas side
(mm)
12.7
Liquid side
(mm)
6.4
Pipe branch-
indoor unit
Gas side
(mm)
12.7
Liquid side
(mm)
6.4
Sound pressure level
Cooling/Heating
(dB(A))
46/48
Sound power level
Cooling/Heating
(dB(A))
63/65