– 65 –
Block distinction
Operation of diagnosis function
Judgment and action
Check
code
Block
Check
code
Cause of operation
Air
conditioner
status
Remarks
Outdoor
P.C. board
Inverter over-current
protective circuit
operates. (Short
time)
All off
Displayed when
error is detected.
Even if trying operation again, all
operations stop immediately. : Replace
P.C. board.
Position-detect circuit
error or short-circuit
between windings of
compressor
All off
Displayed when
error is detected.
1. Even if connecting lead wire of
compressor is removed, position-
detect circuit error occurred. :
Replace P.C. board.
2. Measure resistance between wires of
compressor, and perform short-
circuit. : Replace compressor.
Current-detect circuit
error
All off
Displayed when
error is detected.
Even if trying operation again, all
operations stop immediately. : Replace
P.C. board.
Being out of place,
disconnection or
shortcircuit of the
outdoor heat
exchanger sensor
(TE) or suction temp.
sensor (Ts)
All off
Displayed when
error is detected.
1. Check sensors (TE, TS).
2. Check P.C. board.
Disconnection or
shortcircuit of
discharge temp.
sensor (Td)
All off
Displayed when
error is detected.
1. Check discharge temp. sensor (TD).
2. Check P.C. board
Outdoor fan drive
system error
All off
Displayed when
error is detected.
Position-detect error, over-current
protective operation of outdoor fan drive
system, fan lock, etc. : Replace P.C.
board or fan motor.
Not
displayed
Outdoor heat
exchanger temp.
sensor error
Operation
continues
1. Check outdoor temp. sensor (TO).
2. Check P.C. board.
Outdoor
P.C. board
Compressor drive
output error,
Compressor error
(lock, missing, etc.),
Break down
All off
Displayed when
error is detected.
When 20 seconds passed after start-up,
position-detect circuit error occurred. :
Replace compressor.
Trouble on P.M.V.