– 22 –
Item
Operation flow and applicable data, etc.
Description
1. Basic
operation
1-2.When power supply is reset
1) Based on EEPROM data and DIPSW, setting of the indoor fan
speed and other setting are loaded. During this loading (approx
30 seconds), operation cannot be accepted.
Air speed (rpm)
1-3. Operating mode selection when performing 2-room operation
1) The outdoor unit operation mode conforms to the instructions of the indoor unit that was pressed
first.
2) When combined operation consisting of cooling (dry) and heating, fan and heating, or cleaning
operation and heating is performed, operation conforms to the instructions of the indoor unit that was
pressed first as shown in the following table.
3) The indoor fan stops for the indoor unit that was pressed last and which instructions are ignored.
4) When three or four indoor units are operated concurrently, the priority is also given to operating mode
of the indoor unit which was pressed first as same as the case when two indoor units are operated
concurrently.
No.
Indoor unit
Set operating mode
Actual indoor unit operation
Actual outdoor unit operation
1
Pressed first
Cooling (dry)
Cooling (dry)
Cooling
Pressed last
Cooling (dry)
Cooling (dry)
2
Pressed first
Heating
Heating
Heating
Pressed last
Heating
Heating
3
Pressed first
Fan only
Fan only
Stopped
Pressed last
Fan only
Fan only
4
Pressed first
Fan only
Fan only
Cooling
Pressed last
Cooling (dry)
Cooling (dry)
5
Pressed first
Cooling (dry)
Cooling (dry)
Cooling
Pressed last
Fan only
Fan only
6
Pressed first
Cooling (dry)
Cooling (dry)
Cooling
Pressed last
Heating
Fan stopped
7
Pressed first
Heating
Heating
Heating
Pressed last
Cooling (dry)
Fan stopped
8
Pressed first
Cleaning operation
Cleaning operation
Stopped
Pressed last
Cleaning operation
Cleaning operation
9
Pressed first
Cleaning operation
Cleaning operation
Cooling
Pressed last
Cooling (dry)
Cooling (dry)
10
Pressed first
Cooling (dry)
Cooling (dry)
Cooling
Pressed last
Cleaning operation
Cleaning operation
11
Pressed first
Cleaning operation
Cleaning operation
Stopped
Pressed last
Fan only
Fan only
12
Pressed first
Fan only
Fan only
Stopped
Pressed last
Cleaning operation
Cleaning operation
13
Pressed first
Cleaning operation
Cleaning operation
Stopped
Pressed last
Heating
Fan stopped
14
Pressed first
Heating
Heating
Heating
Pressed last
Cleaning operation
Fan stopped
Summary of Contents for ras-m07g3dv-e
Page 86: ... 85 13 EXPLODED VIEWS AND PARTS LIST 13 1 Indoor Unit ...
Page 93: ......