– 26 –
16
14
12
10
8
6
4
2
0
0
10
20
30
40
50
60
70
80
Inverter output frequency (rps)
Current (A)
• Conditions
Indoor
: DB27˚C/WB19˚C
Outdoor
: DB35˚C
Air flow
: High
Pipe length : 5m x 4
4 units operating
240V
230V
220V
14
12
10
8
6
4
2
0
0
10
100
20
30
40
50
60
70
80
90
Inverter output frequency (rps)
Current (A)
• Conditions
Indoor
: DB20˚C
Outdoor
: DB7˚C / WB6˚C
Air flow
: High
Pipe length : 5m x 4
4 units operating
240V
230V
220V
110
105
100
95
90
85
80
0
10
20
30
40
50
60
70
80
Total pipe length (m)
Coolimg capacity r
atio (%)
• Conditions
Indoor
: DB27˚C/WB19˚C
Outdoor
: DB35˚C
Indoor air flow : High
4 units operating
Standard pipe length 20m
110
105
100
95
90
85
80
0
10
20
30
40
50
60
70
80
Total pipe length (m)
Heating capacity r
a
tio (%)
• Conditions
Indoor
: DB20˚C
Outdoor
: DB7˚C/WB6˚C
Indoor air flow : High
4 units operating
Standard pipe length 20m
50
60
70
80
90
100
110
32
33
34
35
36
37
38
39
40
41 42
43
44
Outdoor temp. (˚C)
Cooling capacity r
atio (%)
• Conditions
Indoor
: DB27˚C/WB19˚C
Indoor air flow : High
Pipe length
: 5m x 4
4 units operating
Current limited start
50
60
70
80
90
100
110
-10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10
Outdoor temp. (˚C)
Heating capacity r
atio (%)
• Conditions
Indoor
: DB20˚C
Air flow
: High
Pipe length
: 5m x 4
4 units operating
2-2-1. Operation Characteristic Curve
<Cooling>
<Heating>
2-2-2. Capacity Variation Ratio According to Outdoor Temperature
<Cooling>
<Heating>
2-2-3. Capacity Variation Ratio According to Pipe Length
<Cooling>
<Heating>
Summary of Contents for RAS-3M26GAV-E1
Page 116: ... 116 MCC 1438 ...
Page 117: ... 117 MCC 818 ...