– 124 –
4
Air outlet panel
Fan
guard
Upper panel
Back panel
Side panel
Front panel
Inverter cover
P.C. board
(Soldered surface)
Fixing plate
(Partition)
Tie-lap ties (2 pcs)
The holder at upper part.
No.
1
Part name
Common
procedure
Procedure
1. Detachment
1) Stop operation of the air conditioner, and turn
“OFF” the power breaker.
2) Remove the side panel. (Ø4 × 10L 3 pcs.)
3) Remove the cord clamp.
(Ø4 × 14L 5 × 2 = 10 pcs.)
Disconnect the connecting cables and power
cord from the terminals.
4) Remove the upper panel. (Ø4 × 10L 6 pcs.)
5) Remove the front panel. (Ø4 × 10L 3 pcs.)
6) Remove the back panel. (Ø4 × 10L 6 pcs.)
7) Remove the air outlet panel. (Ø4 × 10L 8 pcs.)
Remarks
1. Detachment
1) Perform work from item 1) to 5) of
1
.
2) Remove screw (ST1T Ø4 × 10L 1 pc.) of the
upper left part of the inverter cover.
• If removing the inverter cover in this condi-
tion, P.C. board can be checked.
• If there is no space in the upper part of the
upper cabinet, perform work from 6) to 7) of
1
and remove the partition fixing plate
(ST1T Ø4 × 10L 1 pc.).
Be careful to check the inverter because
high-voltage circuit is incorporated in it.
3) Perform discharging by connecting the
discharging resistance (approx. 100
Ω
40W) or
plug of soldering iron to
,
terminals of the
C15 (printed “CAUTION HIGH VOLTAGE” is
attached.) electrolytic capacitor (760µF) on
P.C. board.
Be careful to discharge the capacitor
because the electrolytic capacitor cannot
naturally discharge and voltage remains
according to trouble type in some cases.
NOTE
This capacitor is one with mass capacity.
Therefore, it is dangerous that a large spark
generates if short-circuiting between
,
polarity with screwdriver, etc. for discharging.
4) Remove screw (Ø4 × 10L 2 pcs.) fixing the
valve clamping plate/the inverter box, and
fixing the back panel/the inverter box.
5) Remove various lead wires from the holder at
upper part of the inverter box and cut 2 tie-lap
ties binding each lead wires :
6) Pull the inverter box upward.
7) Disconnect connectors of various lead wires.
2
Inverter
assembly
12-3. Outdoor Unit
Summary of Contents for RAS-3M26GAV-E1
Page 116: ... 116 MCC 1438 ...
Page 117: ... 117 MCC 818 ...