– 80 –
u
Mounting the installation plate directly on
a wall
1) Securely fit the installation plate onto the wall
by screws with the upper and lower catches.
2) To mount the installation plate on a concrete
wall use anchor bolts. Drill the anchor bolt
holes as illustrated in the above figure.
3) Place the level at the top end of the installation
plate, and check that the plate is horizontal.
CAUTION
When installing the installation plate with mounting
screws, do not use anchor bolt holes.
Otherwise the unit may fall down and result in
personal injury and property damage.
Fig. 10-3-4
Fig. 10-3-5
CAUTION
Failure to securely install the unit may result in per-
sonal injury and/or property damage if the unit falls.
• In case of block, brick, concrete or similar type
walls, drill 5 mm dia. holes in the wall.
• Insert clip anchors for the [5] mounting screws.
NOTE
Install the installation plate using between 4 to 6
mounting screws, making sure all four corners are
secure.
Anchor bolt
Projection
15mm or less
5 mm dia. hole
Clip anchor
(local parts)
[5] Mounting screw
Ø4 × 25L
10-3-3. Electrical Work
1. The supply voltage must be the same as the
rated voltage of the air conditioner.
2. Prepare a power source for the exclusive use of
the air conditioner.
NOTE
• Wire type: H07RN-F or 60245IEC66 (1.0 mm²)
• Make sure the wire length is sufficient before
performing wiring work.
Summary of Contents for RAS-3M26GAV-E1
Page 116: ... 116 MCC 1438 ...