Item
3. Outdoor fan
motor control
Operation flow and applicable data, etc.
Description
Outdoor fan speed (rpm)
f0
f1
f2
f3
f4
f5
f6
f7
f8
f9
fA
fB
fC
fD
fE
fF
RAS-1
6
E2AVG-
E
0
300
300
300
360
450
500
550
600
650
700
800
900
900
950
950
Fan speed range
Model name
RAS-18
E2AVG-
E
0
300
300
300
360
450
500
550
600
650
700
800
900
900
950
950
In cooling operation
In heating operation
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
f6
fB
f8
fE
fA
fE
f7
f8
f9
f5
fA
f7
fD
f9
fE
f9
fB
fE
f3
f7
f5
f9
f7
fB
fE
fE
fE
f2
f5
f4
f7
f6
f9
fE
fE
fE
f1
f3
f3
f5
f4
f7
fE
fE
fE
f1
f2
f2
f4
f3
f5
fE
fF
fF
OFF
fB
OFF
fE
f1
fE
To ≥ 5°C
Compressor speed
RAS-16E2
A
VG-E
Hz < 31.8
To ≥ 0°C
To < - 10°C
To ≥ 0°C
When To is abnormal
When To is abnormal
To ≥ 28°C
60.6 ≤
Hz
Hz < 27.6
66.0 ≤
Hz
RAS-16E2
A
VG-E
RAS-18E2AVG-E
RAS-18E2AVG-E
27.6 ≤ Hz < 66.0
25.2 ≤ Hz < 66.0
To ≥ 15°C
To ≥ -3°C
To ≥ 5.5°C
To ≥ -10°C
Fan speed range
Fan speed range
To
To ≥ 38°C
To
To ≥ 10°C
Hz < 25.2
31.8 ≤ Hz < 60.6
Compressor speed
4. Capacity
control
The cooling or heating capacity depending on the load is
adjusted.
According to difference between the setup value of tempera-
ture and the room temperature, the capacity is adjusted by
the compressor revolution.
1) The difference between set
temperature on remote controller
(Ts) and room temperature (Ta)
is calculated.
2) According to the temperature
difference, the correction value of
Hz signal which determines the
compressor speed is set up.
3)
4)
5)
The rotating position and speed
of the motor are detected by the
electromotive force occurred on
the motor winding with operation
of the compressor.
According to the difference
resulted from comparison of the
correction value of Hz signal with
the present operation Hz, the
inverter output and the
commutation timing are varied.
Change the compressor motor
speed by outputting power to the
compressor.
* The contents of control
operation are same in cooling
operation and heating
operation
Set temp. (Ts)
Room temp. (Ta)
Correction of Hz signal
Detection of electromotive force
of compressor motor winding
Detection of motor speed and rotor position
Inverter output change
Commutation timing change
Change of compressor speed
Remote controller
Indoor unit
Ts –Ta
Correction
value of Hz signal ≤ Operating Hz
- 42 -