No.
Part name
P
rocedure
s
Remarks
5
Horizontal louver
6
1) Remove shaft of the horizontal louver
from
drain pan.
Type A:
Push
1 the center
arm
then
remove the other shafts.
Type
B
:
Push
2 the center
arm
then
remove the other shafts.
Horizontal louver
Drain pan
Horizontal louver
Type : A (For 05,07,10,13k)
Type : B (For 16,18k)
Fan motor
1) Follow the procedure item 3 and 4 .
2) Loosen the set screw of the cross flow fan.
3) Remove 2 fixing screws of the motor band.
4) Pull the motor band and the fan motor
outward.
<To re-installation>
- Check the type name of fan motor.
- Keep connector position and arrange fan
motor wires follow figure.
(45°)
Fan motor
connector
Fan motor wire
Hexagon screw driver
Vertical louver
Cross flow fan
Motor band
Fan motor
Screws
3.5 mm
Cross flow fan
Set screw
Fan motor
Body back
5.0 mm
Cross flow fan
Set screw
Fan motor
Body back
Type : A (For 05,07,10,13k)
Type : B (For 16,18k)
- 111 -