– 4
5
–
Table 9-4-2 Approximate value of the sensor (thermistor) resistance (TA, TC)
(= k
Ω
)
Temperature
0°C
10°C
20°C
25°C
30°C
Sensor
Themo. Sensor
35,8
20,7
12,6
10,0
7,92
9-4-3. How to Reduce the Operation Time of
the Anti-Restart Timer
(1) Set the operation mode, temperature, and air
flow rate to be applied with the timer short mode.
(2) Push the [CNL] button while keeping [CHK]
button pushed. In this case, the check mode is
released, and the timer short mode is waited.
(The status is kept even if [CHK] and [CNL]
buttons are released.)
(3) Pushing [START/STOP] buttons sends operation
code + timer short code.
(4) The timer short mode is released by only a
transmission. Therefore, repeat steps from (2) to
perform the timer short mode again.
Fig. 9-4-1
TEMP.
START/STOP
TIMER
WC-E1BE
ECONO.
ON
OFF
RSV
CNL
ACL CHK
FAN
SET
MODE
AUTO
[CHK] button
[CNL] button