– 3 –
1. SPECIFICATIONS
RAS-07YKX/07YAX, RAS-07YK-E/07YA-E, RAS-07YKX-T/07YAX-T
↑
↓
RAS-07YK-E/YA-E
RAS-07YKX/YAX
RAS-07YKX-T/YAX-T
MODEL
ITEM
Cooling
220V–240V
220V
Capacity
kW
*
1
2,10–2,20
2,10
Phase
Single
V
220–240
220
Power source
Hz
50
Power consumption
kW
0,60–0,65
0,60
Power factor
%
96–94
96
V
220V–240V
220V
Running current
Indoor/Outdoor
A
0,15/2,70–0,15/2,72
0,15/2,70
Starting current
A
12
Moisture removal
lit/h
0,8
Indoor (H/M/L)
dB (A)
39 / 33 / 29
Noise
(SPL at 1 meter)
Outdoor (220–240V)
dB (A)
44–45
44
Name of refrigerant
R-22
Refrigerant
Rated volume
kg
0,59
Refrigerant control
Capillary tube
Gas side size
mm
9,52
Connection type
Flare connection
Liquid side size
mm
6,35
Connection type
Flare connection
Maximum length (of one way)
m
*
2
10
Interconnection pipe
Maximum height difference
Indoor unit
Outdoor unit
m
5
Condensate drain pipe
Outer diameter
mm
16
INDOOR UNIT
RAS-07YK-E
RAS-07YKX
RAS-07YKX-T
Height
mm
265
Width
mm
790
Dimensions
Depth
mm
189
Net weight
kg
8
Evaporator type
Finned tube
Indoor fan type
Cross flow fan
High fan
m³/h
550
Medium fan
m³/h
490
Air flow rate
Low fan
m³/h
430
Fan motor output
W
20
Air filter
Polypropylene net filter (Washable)
OUTDOOR UNIT
RAS-07YA-E
RAS-07YAX
RAS-07YAX-T
Height
mm
530
Width
mm
770
Dimensions
Depth
mm
200
Net weight
kg
26
Condenser type
Finned tube
Outdoor fan type
Propeller
Air flow rate (220–240V)
m³/h
1500–1700
1500
Fan motor output
W
18 (UE6-21SJ5P)
18 (UE6-21A5P), 20 (HF-240-20A)
Model
PH80T1-4C
Compressor
Output
W
605
Safety device
Fuse, Overload relay
Auto louver
Yes
Usable outdoor temperature range
°C
21–43
Specifications are subject to change without notice.