– 4
9
–
No.
Part name
Procedure
Remarks
Q
Common
procedure
1) Stop the operation of air-conditioner, and disconnect
the power cord from the AC supply.
2) Remove Electric parts cover.
(2- ST1T Ø4 x 10
l
)
(1-ST1T Ø4 x 10
l
:
07YA-ES &
10YA-ES only)
3) Remove the cord clamp (2- ST2T Ø4 x 12
l
) and
remove the connecting cable.
4) Remove the front cabinet.
(7- ST1T Ø4 x 10
l
with nylon washer)
• Pull the front lower portion toward you, and remove
it pulling out upward.
R
Capacitor for
compressor
1) Remove the fixing screw of the capacitor band.
(1- ST2T Ø4 x 8
l
)
2) Remove the cable connected to the terminal.
S
Capacitor for
fan motor
1) Remove the fixing screw of the capacitor band.
(1- ST2T Ø4 x 8
l
)
2) Remove the cable connected to the terminal.
Refer to [Specifications of Electric Parts]
in pages 10 and 11.
T
Overload
relay
(Except for
07
YA-ES
&
1) Perform the process
Q
above.
2) Remove terminal cover of compressor.
3) Remove overload relay holder and pull overload relay
10YA-ES)
up.
4) Remove Fustons of leads.
Compressor
10-3. Outdoor Unit
Remove 7-ST1T
Ø4 x 10
l
2-ST1T Ø4 x10
l
2-ST2T Ø4 x 12
l
2-ST2T Ø4 x 12
l