Q7 ASD Installation and Operation Manual
109
RX2 Speed Reference #1
Program
⇒
Freq Settings
⇒
RX2 Speed Ref #1
This parameter is used to set the direction, gain, and bias of the RX2 input
terminal when the RX2 terminal is used as the control input while operating in
the Speed Control or the Torque Control mode.
for further information on this setting when
used for Speed control.
for further information on this setting when
used for Torque control.
This parameter sets the RX2 input level that is associated with RX2 Speed
Frequency #1 when operating in the Speed control mode and is associated with
the
when operating in the Torque control mode.
This value is entered as -100 to +100% of the -10 to +10 VDC RX2 input
signal range.
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — -100.0
Maximum — 100.0
Units — %
RX2 Speed Reference #2
Program
⇒
Freq Settings
⇒
RX2 Speed Ref #2
This parameter is used to set the direction, gain, and bias of the RX2 input
terminal when the RX2 terminal is used as the control input while operating in
the Speed Control or the Torque Control mode.
for further information on this setting when
used for Speed control.
for further information on this setting when
used for Torque control.
This parameter sets the RX2 input level that is associated with RX2 Speed
Frequency #2 when operating in the Speed control mode and is associated with
the
when operating in the Torque control mode.
This value is entered as -100 to +100% of the -10 to +10 VDC RX2 input
signal range.
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — -100.0
Maximum — 100.0
Units — %