To disassemble the Battery terminals sub-assembly (after step 15)
15a
The top view of camera
of step 15.
15a1
Remove the screws
01635-042*2 of Shutter
PCB ASSY U520 and
take off the Shutter PCB
ASSY.
Open the cap of
connector before
remove the Shutter
PCB U520 as
shown.
Screw driver
Tweezers
15a2
Remove the screws
01635-010*2 on Mode
PCB ASSY U510.
Desolder the wire joints
as shown.
Screw driver
Soldering iron
15a3
Pull up the Mode PCB
ASSY U510 after the
solder being cleaned.
Watch out the IR
Receiver ASSY
should not be
damaged.
Tweezers
15a4
Remove the screws
01635-042*2 inside the
Battery Chamber.
Screw driver
15a5
Remove the screw
01635-010 outside the
Battery Chamber.
Screw driver
15a6
Pull down the Battery
Chamber ASSY as
shown.
15a7
Remove the screws
01635-164*4 to separate
the Battery Terminal
A600. The camera
disassemble procedure
is finished.