21
Fig. 3.3.7
8. The setting range of Oscilloscope is AC, 500mV/div, 20us/div, “INV”, “ADD” for the observation of the waveform
of G signal (TP602) and B signal (TP600). Press the UP/DOWN button to select the item B_CNT. Then press the
RIGHT button.
Then press UP/DOWN to set G-B signal shown as figure 3.3.8. The waveform within 1H should be adjusted flat.
Then press OK button to return.
Fig. 3.3.8
9. Press the UP/DOWN button to select the item B-BRT. Then Press the RIGHT button.
Then press UP/DOWN to set G-B signal shown as figure 3.3.9. The waveform amplitude of G-B signal should be
adjusted flat. Then press OK button to return.
Fig. 3.3.9
10. Press the UP/DOWN button to select the item HPOS. Then press the RIGHT button.
Press the STROBE button, then white frame will be displayed on LCD as figure 3.3.10. Press UP/DOWN to adjust
this frame to the center of LCD. Then press OK button to return.