– 276 –
Procedure 1: Reading Setting Data from EEPROM
(Read the setting data from EEPROM, including both the factory settings and any modifications made to them on
site.)
1
Push the
+
+
buttons simultaneously and hold for at least 4 seconds.
1
(This number
corresponds to the same number shown on the Remote Controller Operation Diagram.)
* In the case of group control, the unit No. displayed first is the indoor unit No. of the header unit.
At the same time, the CODE No. (DN code) 10 is displayed, and the fan of the selected indoor unit comes
on, with the louver swinging, depending on the model.
2
Each time the
button is pushed, one of the indoor unit No. under group control is
displayed in turn.
2
* The fan of the selected indoor unit comes on, with the flaps swinging, depending on the model.
3
The
button allows you to move the CODE No. (DN code) up/down by one place.
3
4
First, change the CODE No. (DN code) from 10 to 01. (To set filter sign lighting time)
Jot down the setting data displayed.
5
Change the CODE No. (DN code) using the
button.
Again, jot down the setting data displayed.
6
Repeat step 5 until all the setting data has been jotted down. (See the CODE No. list.)
* CODE No. (DN code) go from 01 to FF with a few gaps along the way.
7
When finished, push the
button to bring the system back to normal off state.
6
(It takes the system about 1 minute to become responsive to remote controller operation.)
CODE No. (DN code) necessary at minimum
The type and capacity of the indoor unit are necessary for fan speed setting.
DN
Contents
10
Type
11
Indoor unit capacity
12
Line address
13
Indoor address
14
Group address
UNIT LOUVER
SET DATA
R.C.
No.
UNIT No.
CODE No.
TEMP.
ON / OFF
PROGRAM DAY
TIME
SAVE
3
6
1
5
2
4
FILTER UP/DN
SCHEDULE
FAN
MODE
VENT
FLT.RESET TEST
SET CL
SWING/FIX
UNIT
LOUVER
<Fig. 2 RBC-AMS41E>
TEMP.
ON / OFF
SETTING
SETDATA
UNIT
CODE
No.
No.
R.C.
No.
SET
TIME
TIMER SET
TEST
FILTER
RESET
CL
FAN
SAVE
SWING/FIX
VENT
MODE
UNIT LOUVER
3
6
1
5
2
4
<Fig. 1 RBC-AMT32E>
Remote Controller Operation Diagram
Summary of Contents for MMY-MAP0804HT7JP
Page 23: ... 22 1 Wiring Diagrams 1 1 Outdoor Unit Models MMY MAP0804 MAP1004 and MAP1204 ...
Page 24: ... 23 Models MMY MAP1404 and MAP1604 ...
Page 35: ... 34 1 2 10 Slim Duct Type AP024 AP027 Models MMD AP0244SPH MMD AP0274SPH ...
Page 38: ... 37 1 2 13 High Wall Type 3 series Models MMK AP0073H AP0093H AP0123H AP0153H AP0183H AP0243H ...
Page 52: ... 51 2 5 Parts Layout in Outdoor Unit 8 10 12HP Model MMY MAP0804 MAP1004 MAP1204 ...
Page 53: ... 52 14 16HP Model MMY MAP1404 MAP1604 ...
Page 57: ... 56 2 7 2 Inverter P C board for compressor MCC 1596 A3 IPDU ...
Page 323: ......