54
E
rr
or detected b
y
TCC-LINK central contr
ol de
vice
Chec
k code
Displa
y on
central contr
o
l
de
vice
C05
C06
C12
P30
Outdoor 7-segment displa
y
Sub-code
—
—
—
(L20 is displa
y
ed.)
AI-NET
central contr
ol
remote contr
oller
—
—
—
Detected
position
TCC-LINK
Gener
al-
pur
pose de
vice
I/F
TCC-LINK
Chec
k code name
TCC-LINK centr
al control
de
vice tr
ansmission error
TCC-LINK centr
al control
de
vice receiving error
Interf
ace batch alar
m of
gener
al-pur
pose control
d
e
vices
F
ollo
w
er unit error of
g
roup control
Duplicated centr
a
l
control address
Status
Oper
ation
contin
ued.
Oper
ation
contin
ued.
Oper
ation
contin
ued.
Oper
ation
contin
ued.
Oper
ation
contin
ued.
Err
or detection condition
Signal is not transmit from
centr
al control de
vice
.
Signal is not receiv
ed from
centr
al control de
vice
.
Error w
as input in gener
al-
pur
pose control de
vice
control interf
ace
.
An error occurred in f
ollo
w
e
r
unit of the g
roup control.
([P30] is displa
y
ed only on
the centr
al control remote
controller
.)
Centr
al control addresses
w
ere duplicated.
Chec
k item (position)
•
Chec
k centr
al control de
vice error
.
•
Chec
k comm
unication line error of centr
al control de
vice
.
•
Chec
k setup of end ter
minal resistance
.
•
Chec
k centr
al control de
vice error
.
•
Chec
k comm
unication line error of centr
al control de
vice
.
•
Chec
k setup of end ter
minal resistance
.
•
Chec
k the po
w
er of connecting destination connected de
vice
.
•
Chec
k P
.C
. board error of the connected de
vice
.
•
Chec
k error input.
•
Chec
k the chec
k code of the unit with alar
m.
•
Chec
k the address setup
.
Diff
ers according to error contents of the with
alar
m
E
rr
or detected b
y AI-NET central contr
ol de
vice
Chec
k code
Main
remote
contr
oller
—
—
—
Outdoor 7-segment displa
y
Chec
k code
Sub-code
——
——
——
AI-NET
central contr
ol
remote contr
oller
97
99
b7
Detected
position
AI-NET
AI-NET
AI-NET
Chec
k code name
AI-NET comm
unication
system error
Duplicated netw
or
k
adaptors
Error in indoor g
roup
Status
Oper
ation
contin
ued.
Oper
ation
contin
ued.
Oper
ation
contin
ued.
Err
or detection condition
E07/L07/L03/L08 w
a
s
detected when other indoor
unit in the g
roup w
a
s
def
ectiv
e
.
Multiple netw
or
k adaptors
w
ere connected to
comm
unication line of
remote controller
.
(Detected at centr
a
l
controller side)
Error of f
ollo
w
er unit in the
g
roup
Chec
k item (position)
•
Chec
k m
ultiple netw
or
k adaptors
.
•
Chec
k wire and mis
wir
ing of remote controller
: Only one netw
or
k
adaptor can be connected to comm
unication line of remote
controller
.
•
Chec
k comm
unication line
, mis
wir
ing, and po
w
er of indoor unit.
•
Chec
k comm
unication.
(X,
Y ter
minals)
•
Chec
k netw
or
k adaptor P
.C
. board.
•
Chec
k the centr
al controller (Centr
al control remote controller
, etc.)
•
Chec
k f
ollo
wer unit in the g
roup
.
∗
These errors are concer
ned to comm
unication of remote controllers (A, B) and central system [AI-NET X,
Y], and the main remote
controller displa
ys [E01], [E02], [E03], [E09], or
[E18] in some cases and displa
ys none in other cases according to the contents
.
FILE NO. SVM-05052
Summary of Contents for MMK-AP0072H