Part Names and Functions of the Remote 

Controller

„

Remote controller for the Air to Air Heat Exchanger with DX Coil 
Unit (NRC-01HE)

Operation section 

• One of these remote controllers can be used to control both indoor air 

conditioner units and Air to Air Heat Exchanger with DX Coil Units (up to 8 
units in total). 

• After setting the operation conditions, you can use the units by just pressing 

the ON/OFF button.

• Functions concerning controlling the Air to Air Heat Exchanger with DX Coil 

Unit are explained here. For controlling an air conditioner, refer to the 
owner's manuals supplied with the remote controller and the air conditioner.

 

1

 button (Fan speed select button) (*1)

2

 button (Timer set button)

Used for timer setting

3

 button (Test button)

Used for service. 
Do not use this button in everyday operations.

4

 button (*1) (Ventilation button)

This button is used when the Air to Air Heat 
Exchanger with DX Coil Unit is in a system linked 
with air conditioners. Push the 

 button to turn 

on/off the Air to Air Heat Exchanger with DX Coil 
Unit. Turning on/off the air conditioner also turn on/
off the Air to Air Heat Exchanger with DX Coil Unit.

* No Air to Air Heat Exchanger with DX Coil 

Unit is connected or separate operation of the 
Air to Air Heat Exchanger with DX Coil Unit is 
not set, if “

” appears on the remote 

controller display after pushing the 

 

button.

5

 button (Filter reset button)

Resets “

 FILTER” indication after cleaning.

6

 button (Power save operation)

Use to initiate power saving mode.

Display 

section

Operation 

section

1

3

5

2

7

 button (Swing/Louver direction 

button) (*1)

8

Operation lamp

Lights up during operation.
Blinks when an error occurs or the protective 
device activates. 

9

 button

Turns on the unit when pressed, and turns it off 
when pressed again.

10

 button (Operation mode select button) 

Selects desired operation mode.

11

 button (Unit select button)

Used for selecting a unit while changing settings if 
the remote controls two or more units.

12

 button (Temperature set button)

Adjusts the set temperature.
Select the desired set point by pushing  TEMP. 

 or   TEMP. 

 

13

 button (Ventilation fan speed button)

Used to select the ventilation fan speed

14

 button (Ventilation mode button)

Used to select a ventilation mode.

15

 button (Filter elevating button) (*1)

16

 button (Louver select button) (*1)

OPTION:

Remote controller sensor

Normally the temperature sensor of the indoor unit 
senses the temperature. The temperature around the 
remote controller can also be sensed. For details, 
contact your dealer.
* Do not use the function when the air conditioner is 

controlled in a group.

(*1):
This function is not available for Air to Air Heat 
Exchanger with DX Coil Unit.

” will be displayed for few seconds when the unit is 

running in a system equipped with only the Air to Air 
Heat Exchanger with DX Coil Unit.

13

14

15

12

11

16

8

7

10

SWING/FIX

UNIT  LOUVER

UNIT  LOUVER

11-EN

12-EN

+00ET99915201_00Ta.book  Page 6  Tuesday, February 15, 2011  6:45 PM

Summary of Contents for MMD-VN1002HEX1E

Page 1: ...Coil Unit Model name Model with a humidifier MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE Model without a humidifier MMD VN502HEXE MMD VN802HEXE MMD VN1002HEXE Owner s Manual For commercial use Owner s Manual 1 English 00ET99915201_00Ta book Page 1 Tuesday February 15 2011 6 45 PM ...

Page 2: ...roughly acquainted with the knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigeran...

Page 3: ...g installation servicing and removal Use of a stand more than 50 cm high to clean the filter of the Air to Air Heat Exchanger with DX Coil Unit or to carry out other such jobs constitutes working at heights Due to the danger of falling off the stand and injuring yourself while working at heights this kind of work should not be done by unqualified individuals When this kind of work must be carried ...

Page 4: ...erson 1 to refit the unit Do not set the circuit breaker to the ON position until the unit has been refitted Do not move or repair any unit by yourself Since there is high voltage inside the unit you may get electric shock when removing the cover and main unit Do not modify the products Do not also disassemble or modify the parts It may cause a fire electric shock or injury Relocation When the Air...

Page 5: ...ndle with packing band or may get injured in case of broken band 2 cartons 91 kg 2 Part Names Air to Air Heat Exchanger with DX Coil Unit Separately sold parts Remote controller for the Air to Air Heat Exchanger with DX Coil Unit NRC 01HE SA Supply air RA Return air EA Exhaust air OA Outdoor air Inspection cover for the heat exchange element Earth screw in electrical control box Drain hole Connect...

Page 6: ...X Coil Unit Outdoor unit Remote controller NRC 01HE RBC AMT32E Air conditioner Air conditioner Air to Air Heat Exchanger with DX Coil Unit Air to Air Heat Exchanger with DX Coil Unit When the Air to Air Heat Exchanger with DX Coil Unit system linked with indoor air conditioners is used set the Air to Air Heat Exchanger with DX Coil Unit as Follower referring to Setting the address manually using t...

Page 7: ...he remote controller display after pushing the button 5 button Filter reset button Resets FILTER indication after cleaning 6 button Power save operation Use to initiate power saving mode Display section Operation section 1 3 5 2 6 4 7 button Swing Louver direction button 1 8 Operation lamp Lights up during operation Blinks when an error occurs or the protective device activates 9 button Turns on t...

Page 8: ... mode 17 Louver lock indicator 1 18 UNIT No indicator The number of the Air to Air Heat Exchanger with DX Coil Unit selected using the UNIT button or that of the unit in which an error has occurred 19 Central control indicator Displayed when a central control device such as a central controller is also used If the central control device prohibits the use of local remote controllers blinks when any...

Page 9: ... the outdoor air exhaustion Inflow of humidity and smells from the toilet and kitchen is reduced When SA EA is selected the volume of the outdoor air exhaustion is larger than that of the indoor air supply Outflow of smells and floating bacteria into a corridor or other places is reduced Consult your dealer if the setting of the air volume imbalance seems incorrect Changing ventilation mode 1 Push...

Page 10: ...mount of time has passed between the nighttime heat purge operation becoming on standby and the monitoring operation starting The time is set between 1 48 hours in 1 hour steps 2 The indoor temperature is 3 C or more higher than the outdoor temperature and the indoor temperature is 2 C or more higher than the temperature set for the operation The conditions to pause the nighttime heat purge operat...

Page 11: ...s Hours 7 Installation Location Do not install the unit in places where the outside temperature falls below 5 C Avoid installing near machines emitting high frequency waves Not suitable for chemical plants such as liquefied carbon dioxide refrigerant plants A failure may occur in certain locations such as the following Areas with large amount of oil droplets including machine oil or vapors Salty a...

Page 12: ...et of the indoor unit is blocked NOTE When the protective device activates turn off the power switch remove the cause and then restart running Cooling Heating operations Each unit can be controlled individually However indoor units connected to the same outdoor unit cannot perform cooling and heating simultaneously When you attempt simultaneous operation indoor units performing cooling are stopped...

Page 13: ...t exchanger etc expand and contract slightly due to change of temperature indication is lit When cooling operation cannot be performed because another indoor unit performs heating operation Is outdoor temperature out of operation temperature range indication is lit When the manager of the Air to Air Heat Exchanger with DX Coil Unit has fixed the operation to COOL or HEAT and an operation contrary ...

Page 14: ...the indoor unit will be deleted 3 After confirmation push button to return to the usual display Check code Indoor unit No in which an error occurred 3 2 1 11Specifications Model with a humidifier Model without a humidifier Sound Power Level is less than 70 dBA MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE MMD VNK1002HEXE2 Type Function Cooling and heating dual purpose type Unit configuration Discr...

Page 15: ...chinery described below Generic Denomination Air conditioner Air to Air Heat Exchanger with DX Coil Unit Model type MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE MMD VNK1002HEXE2 MMD VN502HEXE MMD VN802HEXE MMD VN1002HEXE MMD VN1002HEXE2 Commercial name TOSHIBA Air to Air Heat Exchanger with DX Coil Unit Complies with the provisions of the Machinery Directive Directive 2006 42 EC and the regulatio...

Page 16: ...CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00ET99915201_00Ta book Page 29 Tuesday February 15 2011 6 45 PM ...

Reviews: