Air to Air Heat Exchanger with DX Coil Unit

Owner’s Manual

Air to Air Heat Exchanger with DX Coil Unit

Owner’s Manual

CAUTION

If any of the following conditions occur, turn off the main power supply switch and immediately contact the dealer:

• Switch operation does not work properly.
• The main power fuse often blows out, or the circuit breaker is often activated.
• A foreign matter or water fall inside the Air to Air Heat Exchanger with DX Coil Unit.
• When the Air to Air Heat Exchanger with DX Coil Unit does not operate even after the cause of the protective device 

activation has been removed.

• Any other unusual conditions are observed.

Confirmation and check

Confirmation of error log

1. Check the errors according to the above procedure.
2. Ask an authorized dealer or qualified service (maintenance) professional to repair or maintain the Air to Air Heat 

Exchanger with DX Coil Unit.

3. More details of the check code are explained in Service Manual.

When an error occurred in the Air to Air Heat Exchanger with DX Coil 
Unit, the check code and the indoor unit No. appear on the display 
part of the remote controller.
The check code is only displayed during the operation.
If the display disappears, operate the Air to Air Heat Exchanger with 
DX Coil Unit according to the following “Confirmation of error log” for 
confirmation.

When an error occurred on the Air to Air Heat Exchanger with DX 
Coil Unit, the error log can be confirmed with the following 
procedure. (The error log is stored in memory up to 4 errors.)
The error can be confirmed from both operating status and stop 
status.

Procedure

Description

1

When 

 and 

 buttons are pushed simultaneously for 4 

seconds or more, the following display appears.
If [

 Service check] is displayed, the mode enters in the error 

log mode.
• [01 : Order of error log] is displayed in CODE No. window.
• [Check code] is displayed.
• [Indoor unit address in which an error occurred] is displayed in 

UNIT No..

2

Every pushing of [ 

 /

 

 ] button used to set temperature, the error log stored in memory is displayed in 

order.
The numbers in CODE No. indicate CODE No. [01] (latest) to [04] (oldest).

CAUTION

Do not push 

 button because all the error log of the indoor unit will be deleted.

3

After confirmation, push 

 button to return to the usual display.

Check code

Indoor unit No. in which 

an error occurred

3

2

1

11

Specifications

„

Model with a humidifier

„

Model without a humidifier

* Sound Power Level is less than 70 dBA

MMD-VNK502HEXE

MMD-VNK802HEXE

MMD-VNK1002HEXE

MMD-VNK1002HEXE2

Type

Function

Cooling and heating dual purpose type

Unit configuration

Discrete type

Voltage

220-240V~, 50Hz/

220V~, 60Hz

220-240V~, 50Hz/

220V~, 60Hz

220-240V~, 50Hz

220V~, 60Hz

Equivalent HP

1.0

1.7

2

2

Refrigerant

R410A

Outdoor air 

thermal load 

handling 

capacity

cooling 

capacity

(kw)

4.10(1.30)

6.56(2.06)

8.25(2.32)

8.25(2.32)

heating 

capacity

(kw)

5.53(2.33)

8.61(3.61)

10.92(4.32)

10.92(4.32)

Air Volume

m

3

/h

500/500

800/800

950/950

950/950

Fan speed

Extra 

high

High

Low

Extra 

high

High

Low

Extra 

high

High

Low

Extra 

high

High

Low

Power consumption

W

305/

365

285/

350

240/

290

530/

620

485/

575

350/

400

575

565

520

750

685

545

External Static Pressure

Pa

95/175 85/150 95/135

105/

165

85/140 90/110

110

90

115

155

110

80

Humidification level

kg/h

3.0/3.0

5.0/5.0

6.0/6.0

6.0/6.0

Sound pressure level

dB

36.5/

39.0

35.5/

37.0

33.5/

35.5

40.0/

42.0

39.0/

41.0

38.0/

39.0

42.0

41.0

39.0

42.5

41.0

39.0

External 

dimensions

Height

430

430

Width

1140

1189

Depth

1690

1739

Weight

kg

91

111

112

114

MMD-VN502HEXE

MMD-VN802HEXE

MMD-VN1002HEXE

MMD-VN1002HEXE2

Type

Function

Cooling and heating dual purpose type

Unit configuration

Discrete type

Voltage

220-240V~, 50Hz/

220V~, 60Hz

220-240V~, 50Hz/

220V~, 60Hz

220-240V~, 50Hz

220V~, 60Hz

Equivalent HP

1.0

1.7

2

2

Refrigerant

R410A

Outdoor air 

thermal load 

handling 

capacity

cooling 

capacity

(kw)

4.10(1.30)

6.56(2.06)

8.25(2.32)

8.25(2.32)

heating 

capacity

(kw)

5.53(2.33)

8.61(3.61)

10.92(4.32)

10.92(4.32)

Air Volume

m

3

/h

500/500

800/800

950/950

950/950

Notch

Extra 

high

High

Low

Extra 

high

High

Low

Extra 

high

High

Low

Extra 

high

High

Low

Power consumption

W

300/

365

280/

350

235/

250

505/

595

465/

555

335/

390

550

545

485

720

665

530

External Static Pressure

Pa

120/

200

105/

170

115/

150

120/

190

100/

155

105/

130

135

120

105

195

160

130

Sound pressure level

dB

37.5/

40.0

36.5/

38.0

34.5/

36.5

41.0/

43.0

40.0/

42.0

38.0/

37.0

43.0

42.0

40.0

43.5

42.0

40.0

External 

dimensions

Height

430

430

Width

1140

1189

Depth

1690

1739

Weight

kg

84

100

101

103

25-EN

26-EN

+00ET99915201_00Ta.book  Page 13  Tuesday, February 15, 2011  6:45 PM

Summary of Contents for MMD-VN1002HEX1E

Page 1: ...Coil Unit Model name Model with a humidifier MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE Model without a humidifier MMD VN502HEXE MMD VN802HEXE MMD VN1002HEXE Owner s Manual For commercial use Owner s Manual 1 English 00ET99915201_00Ta book Page 1 Tuesday February 15 2011 6 45 PM ...

Page 2: ...roughly acquainted with the knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigeran...

Page 3: ...g installation servicing and removal Use of a stand more than 50 cm high to clean the filter of the Air to Air Heat Exchanger with DX Coil Unit or to carry out other such jobs constitutes working at heights Due to the danger of falling off the stand and injuring yourself while working at heights this kind of work should not be done by unqualified individuals When this kind of work must be carried ...

Page 4: ...erson 1 to refit the unit Do not set the circuit breaker to the ON position until the unit has been refitted Do not move or repair any unit by yourself Since there is high voltage inside the unit you may get electric shock when removing the cover and main unit Do not modify the products Do not also disassemble or modify the parts It may cause a fire electric shock or injury Relocation When the Air...

Page 5: ...ndle with packing band or may get injured in case of broken band 2 cartons 91 kg 2 Part Names Air to Air Heat Exchanger with DX Coil Unit Separately sold parts Remote controller for the Air to Air Heat Exchanger with DX Coil Unit NRC 01HE SA Supply air RA Return air EA Exhaust air OA Outdoor air Inspection cover for the heat exchange element Earth screw in electrical control box Drain hole Connect...

Page 6: ...X Coil Unit Outdoor unit Remote controller NRC 01HE RBC AMT32E Air conditioner Air conditioner Air to Air Heat Exchanger with DX Coil Unit Air to Air Heat Exchanger with DX Coil Unit When the Air to Air Heat Exchanger with DX Coil Unit system linked with indoor air conditioners is used set the Air to Air Heat Exchanger with DX Coil Unit as Follower referring to Setting the address manually using t...

Page 7: ...he remote controller display after pushing the button 5 button Filter reset button Resets FILTER indication after cleaning 6 button Power save operation Use to initiate power saving mode Display section Operation section 1 3 5 2 6 4 7 button Swing Louver direction button 1 8 Operation lamp Lights up during operation Blinks when an error occurs or the protective device activates 9 button Turns on t...

Page 8: ... mode 17 Louver lock indicator 1 18 UNIT No indicator The number of the Air to Air Heat Exchanger with DX Coil Unit selected using the UNIT button or that of the unit in which an error has occurred 19 Central control indicator Displayed when a central control device such as a central controller is also used If the central control device prohibits the use of local remote controllers blinks when any...

Page 9: ... the outdoor air exhaustion Inflow of humidity and smells from the toilet and kitchen is reduced When SA EA is selected the volume of the outdoor air exhaustion is larger than that of the indoor air supply Outflow of smells and floating bacteria into a corridor or other places is reduced Consult your dealer if the setting of the air volume imbalance seems incorrect Changing ventilation mode 1 Push...

Page 10: ...mount of time has passed between the nighttime heat purge operation becoming on standby and the monitoring operation starting The time is set between 1 48 hours in 1 hour steps 2 The indoor temperature is 3 C or more higher than the outdoor temperature and the indoor temperature is 2 C or more higher than the temperature set for the operation The conditions to pause the nighttime heat purge operat...

Page 11: ...s Hours 7 Installation Location Do not install the unit in places where the outside temperature falls below 5 C Avoid installing near machines emitting high frequency waves Not suitable for chemical plants such as liquefied carbon dioxide refrigerant plants A failure may occur in certain locations such as the following Areas with large amount of oil droplets including machine oil or vapors Salty a...

Page 12: ...et of the indoor unit is blocked NOTE When the protective device activates turn off the power switch remove the cause and then restart running Cooling Heating operations Each unit can be controlled individually However indoor units connected to the same outdoor unit cannot perform cooling and heating simultaneously When you attempt simultaneous operation indoor units performing cooling are stopped...

Page 13: ...t exchanger etc expand and contract slightly due to change of temperature indication is lit When cooling operation cannot be performed because another indoor unit performs heating operation Is outdoor temperature out of operation temperature range indication is lit When the manager of the Air to Air Heat Exchanger with DX Coil Unit has fixed the operation to COOL or HEAT and an operation contrary ...

Page 14: ...the indoor unit will be deleted 3 After confirmation push button to return to the usual display Check code Indoor unit No in which an error occurred 3 2 1 11Specifications Model with a humidifier Model without a humidifier Sound Power Level is less than 70 dBA MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE MMD VNK1002HEXE2 Type Function Cooling and heating dual purpose type Unit configuration Discr...

Page 15: ...chinery described below Generic Denomination Air conditioner Air to Air Heat Exchanger with DX Coil Unit Model type MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE MMD VNK1002HEXE2 MMD VN502HEXE MMD VN802HEXE MMD VN1002HEXE MMD VN1002HEXE2 Commercial name TOSHIBA Air to Air Heat Exchanger with DX Coil Unit Complies with the provisions of the Machinery Directive Directive 2006 42 EC and the regulatio...

Page 16: ...CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00ET99915201_00Ta book Page 29 Tuesday February 15 2011 6 45 PM ...

Reviews: