Air to Air Heat Exchanger with DX Coil Unit

Owner’s Manual

EN

Air to Air Heat Exchanger with DX Coil Unit

Owner’s Manual

„

Warning Indications on the Air to Air Heat Exchanger with DX 
Coil Unit

Warning indication

Description

WARNING

ELECTRICAL SHOCK HAZARD

Disconnect all remote electric power supplies before servicing.

WARNING

Moving parts. 
Do not operate unit with inspection cover removed. 
Stop the unit before the servicing.

CAUTION

High temperature parts.
You might get burned when removing this cover.

CAUTION

Do not touch the aluminum fins of the unit.
Doing so may result in injury.

WARNING

ELECTRICAL SHOCK HAZARD

Disconnect all remote 
electric power supplies 
before servicing.

WARNING

Moving parts.
Do not operate unit with 
inspection cover removed. 
Stop the unit before the servicing.

CAUTION

High temperature parts.
You might get burned 
when removing this cover.

CAUTION

Do not touch the aluminum 
fins of the unit.
Doing so may result in injury.

1

Precautions for Safety

WARNING

General

• Carefully read Owner’s Manual before starting the Air to Air Heat Exchanger with DX Coil Unit. There are many 

important things to keep in mind for daily operation.

• Ask for installation to be performed by the dealer or a professional. Only a qualified installer (*1) is able to install an 

Air to Air Heat Exchanger with DX Coil Unit. If a non-qualified person installs an Air to Air Heat Exchanger with DX 
Coil Unit, it may result in problems such as fire, electric shock, injury, water leakage, noise and vibration.

• Do not expose your body to cool air directly for a long time and do not cool yourself excessively.

Doing so may result in deteriorated physical condition and ill health.

• Consult the shop where you purchased Air to Air Heat Exchanger with DX Coil Unit if Air to Air Heat Exchanger with 

DX Coil Unit (cooling and heating) is not performed properly as a refrigerant leakage may be the cause. Confirm the 
repair details with a qualified service person(*1) when the repair includes additional charging of the refrigerant.

• The refrigerant used for Toshiba air conditioner is safe.
• Usually, the refrigerant does not leak. If it should leak and catch fire on a fan heater, stove, or gas range, a toxic 

gas will be produced.

• Install a circuit breaker that meets the specifications in the installation manual and the stipulations in the local 

regulations and laws.

• Do not wash the Air to Air Heat Exchanger with DX Coil Unit. Doing so may result in electric shock.
• When the Air to Air Heat Exchanger with DX Coil Unit is operated with a combustion appliance in the same place, be 

careful of ventilation to let fresh air enter the room. Poor ventilation causes oxygen shortage.

• Be sure to stop running the air conditioner and turn off the breaker before cleaning.

Otherwise, injury may result as the fan is rotating at high speed inside the unit.

• Wear protective gloves and safety work clothing during installation, servicing and removal.
• Use of a stand more than 50 cm high to clean the filter of the Air to Air Heat Exchanger with DX Coil Unit or to carry 

out other such jobs constitutes working at heights. Due to the danger of falling off the stand and injuring yourself while 
working at heights, this kind of work should not be done by unqualified individuals. When this kind of work must be 
carried out, do not do it yourself but ask a qualified installer (*1) or a qualified service person (*1) to do it for you.

• Do not place any combustion appliance in a place where it is directly exposed to the wind of Air to Air Heat Exchanger 

with DX Coil Unit, otherwise it may cause imperfect combustion.

Transportation and storage

• Transport it by the truck or the forklift. Transport it by six people or more when the person transports it temporarily. 

The waist etc. might be hurt when not following it.

• When transporting the Air to Air Heat Exchanger with DX Coil Unit, wear shoes with protective toe caps, protective 

gloves, and other protective clothing.

• When transporting the Air to Air Heat Exchanger with DX Coil Unit, do not take hold of the bands around the packing 

carton. You may injure yourself if the bands should break.

• When stacking the packing cartons for storage or transportation, read the precautions written on the packing cartons. 

Failure to heed the precautions may cause the stack to collapse.

• You shall ensure that the Air to Air Heat Exchanger with DX Coil Unit is transported in stable condition. If you find any 

part of the product broken, contact your dealer.

Installation

• Only a qualified installer(*1) or qualified service person(*1) is allowed to carry out the electrical work of the Air to Air 

Heat Exchanger with DX Coil Unit. Under no circumstances must this work be done by an unqualified individual since 
failure to carry out the work properly may result in electric shocks and/or electrical leaks.

• After the installation work has been completed, have the installer explain about the circuit breaker positions. In the 

event that trouble has occurred in the Air to Air Heat Exchanger with DX Coil Unit, set the circuit breaker to the OFF 
position, and contact a service person. (*1)

• If you install the unit in a small room, take appropriate measures to prevent the refrigerant from exceeding the limit 

concentration even if it leaks. Consult the dealer from whom you purchased the air conditioner when you implement 
the measures. Accumulation of highly concentrated refrigerant may cause an oxygen deficiency accident.

• Do not install the Air to Air Heat Exchanger with DX Coil Unit in a location that may be subject to a risk of expire to a 

combustible gas. If a combustible gas leaks and becomes concentrated around the unit, a fire may occur.

• Be sure to use the company-specified products for the separately purchased parts. Use of non-specified products 

may result in fire, electric shock, water leakage, etc. Have the installation performed by a professional.

• Confirm that earthing is performed correctly. 

3-EN

4-EN

+00ET99915201_00Ta.book  Page 2  Tuesday, February 15, 2011  6:45 PM

Summary of Contents for MMD-VN1002HEX1E

Page 1: ...Coil Unit Model name Model with a humidifier MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE Model without a humidifier MMD VN502HEXE MMD VN802HEXE MMD VN1002HEXE Owner s Manual For commercial use Owner s Manual 1 English 00ET99915201_00Ta book Page 1 Tuesday February 15 2011 6 45 PM ...

Page 2: ...roughly acquainted with the knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigeran...

Page 3: ...g installation servicing and removal Use of a stand more than 50 cm high to clean the filter of the Air to Air Heat Exchanger with DX Coil Unit or to carry out other such jobs constitutes working at heights Due to the danger of falling off the stand and injuring yourself while working at heights this kind of work should not be done by unqualified individuals When this kind of work must be carried ...

Page 4: ...erson 1 to refit the unit Do not set the circuit breaker to the ON position until the unit has been refitted Do not move or repair any unit by yourself Since there is high voltage inside the unit you may get electric shock when removing the cover and main unit Do not modify the products Do not also disassemble or modify the parts It may cause a fire electric shock or injury Relocation When the Air...

Page 5: ...ndle with packing band or may get injured in case of broken band 2 cartons 91 kg 2 Part Names Air to Air Heat Exchanger with DX Coil Unit Separately sold parts Remote controller for the Air to Air Heat Exchanger with DX Coil Unit NRC 01HE SA Supply air RA Return air EA Exhaust air OA Outdoor air Inspection cover for the heat exchange element Earth screw in electrical control box Drain hole Connect...

Page 6: ...X Coil Unit Outdoor unit Remote controller NRC 01HE RBC AMT32E Air conditioner Air conditioner Air to Air Heat Exchanger with DX Coil Unit Air to Air Heat Exchanger with DX Coil Unit When the Air to Air Heat Exchanger with DX Coil Unit system linked with indoor air conditioners is used set the Air to Air Heat Exchanger with DX Coil Unit as Follower referring to Setting the address manually using t...

Page 7: ...he remote controller display after pushing the button 5 button Filter reset button Resets FILTER indication after cleaning 6 button Power save operation Use to initiate power saving mode Display section Operation section 1 3 5 2 6 4 7 button Swing Louver direction button 1 8 Operation lamp Lights up during operation Blinks when an error occurs or the protective device activates 9 button Turns on t...

Page 8: ... mode 17 Louver lock indicator 1 18 UNIT No indicator The number of the Air to Air Heat Exchanger with DX Coil Unit selected using the UNIT button or that of the unit in which an error has occurred 19 Central control indicator Displayed when a central control device such as a central controller is also used If the central control device prohibits the use of local remote controllers blinks when any...

Page 9: ... the outdoor air exhaustion Inflow of humidity and smells from the toilet and kitchen is reduced When SA EA is selected the volume of the outdoor air exhaustion is larger than that of the indoor air supply Outflow of smells and floating bacteria into a corridor or other places is reduced Consult your dealer if the setting of the air volume imbalance seems incorrect Changing ventilation mode 1 Push...

Page 10: ...mount of time has passed between the nighttime heat purge operation becoming on standby and the monitoring operation starting The time is set between 1 48 hours in 1 hour steps 2 The indoor temperature is 3 C or more higher than the outdoor temperature and the indoor temperature is 2 C or more higher than the temperature set for the operation The conditions to pause the nighttime heat purge operat...

Page 11: ...s Hours 7 Installation Location Do not install the unit in places where the outside temperature falls below 5 C Avoid installing near machines emitting high frequency waves Not suitable for chemical plants such as liquefied carbon dioxide refrigerant plants A failure may occur in certain locations such as the following Areas with large amount of oil droplets including machine oil or vapors Salty a...

Page 12: ...et of the indoor unit is blocked NOTE When the protective device activates turn off the power switch remove the cause and then restart running Cooling Heating operations Each unit can be controlled individually However indoor units connected to the same outdoor unit cannot perform cooling and heating simultaneously When you attempt simultaneous operation indoor units performing cooling are stopped...

Page 13: ...t exchanger etc expand and contract slightly due to change of temperature indication is lit When cooling operation cannot be performed because another indoor unit performs heating operation Is outdoor temperature out of operation temperature range indication is lit When the manager of the Air to Air Heat Exchanger with DX Coil Unit has fixed the operation to COOL or HEAT and an operation contrary ...

Page 14: ...the indoor unit will be deleted 3 After confirmation push button to return to the usual display Check code Indoor unit No in which an error occurred 3 2 1 11Specifications Model with a humidifier Model without a humidifier Sound Power Level is less than 70 dBA MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE MMD VNK1002HEXE2 Type Function Cooling and heating dual purpose type Unit configuration Discr...

Page 15: ...chinery described below Generic Denomination Air conditioner Air to Air Heat Exchanger with DX Coil Unit Model type MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE MMD VNK1002HEXE2 MMD VN502HEXE MMD VN802HEXE MMD VN1002HEXE MMD VN1002HEXE2 Commercial name TOSHIBA Air to Air Heat Exchanger with DX Coil Unit Complies with the provisions of the Machinery Directive Directive 2006 42 EC and the regulatio...

Page 16: ...CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00ET99915201_00Ta book Page 29 Tuesday February 15 2011 6 45 PM ...

Reviews: