Air to Air Heat Exchanger with DX Coil Unit

Owner’s Manual

Air to Air Heat Exchanger with DX Coil Unit

Owner’s Manual

Operation

• Before opening the electrical control cover or inspection cover or maintenance cover of the Air to Air Heat Exchanger 

with DX Coil Unit, set the circuit breaker to the OFF position. Failure to set the circuit breaker to the OFF position may 
result in electric shocks through contact with the interior parts. Only a qualified installer(*1) or qualified service 
person(*1) is allowed to remove the electrical control cover or inspection cover or maintenance cover of the Air to Air 
Heat Exchanger with DX Coil Unit and do the work required.

• Inside the Air to Air Heat Exchanger with DX Coil Unit are high-voltage areas and rotating parts. Due to the danger 

of electric shocks or of your fingers or physical objects becoming trapped in the rotating parts, do not remove the 
electrical control cover, inspection cover or maintenance cover of the Air to Air Heat Exchanger with DX Coil Unit. 
When work involving the removal of these parts is required, contact a qualified installer or a qualified service person.

• Do not modify the products. Do not also disassemble or modify the parts. It may cause a fire, electric shock or injury.
• Use of a stand more than 50 cm high to clean the filter or heat exchange element of the Air to Air Heat Exchanger 

with DX Coil Unit or to carry out other such jobs constitutes working at heights. Due to the danger of falling off the 
stand and injuring yourself while working at heights, this kind of work should not be done by unqualified individuals. 
When this kind of work must be carried out, do not do it yourself but ask a qualified installer(*1) or a qualified service 
person(*1) to do it for you.

• Do not touch the aluminum fin of the Air to Air Heat Exchanger with DX Coil Unit or outdoor unit. You may injure 

yourself if you do so. If the fin must be touched, do not touch it yourself but contact a qualified installer(*1) or a 
qualified service person(*1).

• Never insert your finger or a stick into the air intake or outlet.

Doing so may result injury as the fan is rotating at high speed inside the unit. 

• Be sure to stop running the Air to Air Heat Exchanger with DX Coil Unit and turn off the breaker before cleaning.

Otherwise, injury may result as the fan is rotating at high speed inside the unit.

• Do not run or stop running the unit when flammable gas is leaking.

A gas explosion may occur. Open the window to ventilate the room if flammable gas is leaking.

Repairs

• When you have noticed that some kind of trouble (such as when an error display has appeared, there is a smell of 

burning, abnormal sounds are heard, the Air to Air Heat Exchanger with DX Coil Unit falls to cool, heat or water is 
leaking) has occurred in the Air to Air Heat Exchanger with DX Coil Unit, do not touch the Air to Air Heat Exchanger 
with DX Coil Unit yourself but set the circuit breaker to the OFF position, and contact a qualified service person(*1). 
Take steps to ensure that the power will not be turned on (by marking “out of service” near the circuit breaker, for 
instance) until qualified service person arrives. Continuing to use the Air to Air Heat Exchanger with DX Coil Unit in 
the trouble status may cause mechanical problems to escalate or result in electric shocks, or other failure.

• If you have discovered that there is a danger of the Air to Air Heat Exchanger with DX Coil Unit’s falling, do not 

approach the Air to Air Heat Exchanger with DX Coil Unit but set the circuit breaker to the OFF position, and contact 
a qualified installer(*1) or a qualified service person(*1) to refit the unit. Do not set the circuit breaker to the ON 
position until the unit has been refitted.

• Do not move or repair any unit by yourself. Since there is high voltage inside the unit, you may get electric shock 

when removing the cover and main unit.

• Do not modify the products. Do not also disassemble or modify the parts. It may cause a fire, electric shock or injury.

Relocation

• When the Air to Air Heat Exchanger with DX Coil Unit is to be relocated, do not relocate it yourself but contact a 

qualified installer(*1) or a qualified service person(*1). Failure to relocate the Air to Air Heat Exchanger with DX Coil 
Unit properly may result in electric shocks and/or a fire.

• Do not touch any switches with wet finger, otherwise you may get an electric shock.

(*1) Refer to the “Definition of Qualified Installer or Qualified Service Person.”

CAUTION

TO DISCONNECT THE APPLIANCE FROM THE MAINS SUPPLY

Means for disconnection having a contact separation in all poles at least 3 mm must be incorporated in the fixed 

wiring in accordance with the wiring rules.

THE INSTALLATION FUSE (All types can be used) MUST BE USED FOR THE POWER SUPPLY LINE OF 

THIS Air to Air Heat Exchanger with DX Coil Unit.
CAUTIONS ABOUT INSTALLATION (Be sure to confirm the following cautions.)

• Certainly lay the drain hose for perfect draining. Bad drainage may cause flooding in the house and getting furniture 

wet.

• Make sure to connect the Air to Air Heat Exchanger with DX Coil Unit to an exclusive power supply of the rated 

voltage, otherwise the unit may break down or cause a fire.

CAUTIONS ABOUT OPERATION

• Do not use this Air to Air Heat Exchanger with DX Coil Unit for special purpose such as preserving food, precision 

instruments, art objects, breeding animals, car, vessel, etc.

• If the Air to Air Heat Exchanger with DX Coil Unit will not be used for a considerably long time, turn off the main switch 

or the circuit breaker, for safety.

• To make the Air to Air Heat Exchanger with DX Coil Unit operate in its original performance, operate it within the range 

of the operating temperature specified in the instructions. Otherwise it may cause a malfunction, or water leak from 
the unit.

• Prevent any liquid from falling into the remote controller. Do not spill juice, water or any kind of liquid.
• Do not leave flammable sprays or other flammable materials near the Air to Air Heat Exchanger with DX Coil Unit, 

and do not spray flammable aerosol directly to the Air to Air Heat Exchanger with DX Coil Unit. They may catch fire.

• Do not pour or spray water or detergent on the electric parts.

Doing so may cause electric leakage and result in a fire, electric shocks and/or injury.

• Do not install the unit and inside air intake in a place such as a machine factory, chemical plant, or research institute, 

where acids, alkaline, organic solvents, or coating materials are handled and toxic gases and/or corrosive gases may 
be produced.
Otherwise, gas poisoning may occur and/or the inside of the unit may be eroded or deteriorated. The deterioration 
and erosion may result in a fire.

• Do not use the unit in a place where it is hot (40°C or higher) or where much oily smoke is produced, and do not 

directly expose the unit to flame.
Doing so may result in a fire.

• Do not expose animals or plants to the wind from the unit.

Doing so may harm the animal or plant.

• Do not use a flammable spray near the unit or inside air intake.

Doing so may result in a fire.

• Fix the parts such as the inspection cover firmly.
• Confirm that the outdoor unit and the heat storage unit are fixed on the base securely.

Inappropriate fixing may cause them to fall down and an accident may result.

• Stop running the unit if it vibrates abnormally.

The unit or parts of it may fall and an injury may result.

5-EN

6-EN

+00ET99915201_00Ta.book  Page 3  Tuesday, February 15, 2011  6:45 PM

Summary of Contents for MMD-VN1002HEX1E

Page 1: ...Coil Unit Model name Model with a humidifier MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE Model without a humidifier MMD VN502HEXE MMD VN802HEXE MMD VN1002HEXE Owner s Manual For commercial use Owner s Manual 1 English 00ET99915201_00Ta book Page 1 Tuesday February 15 2011 6 45 PM ...

Page 2: ...roughly acquainted with the knowledge related to this work The qualified installer who is allowed to do the refrigerant handling and piping work involved in installation relocation and removal has the qualifications pertaining to this refrigerant handling and piping work as stipulated by the local laws and regulations and he or she is a person who has been trained in matters relating to refrigeran...

Page 3: ...g installation servicing and removal Use of a stand more than 50 cm high to clean the filter of the Air to Air Heat Exchanger with DX Coil Unit or to carry out other such jobs constitutes working at heights Due to the danger of falling off the stand and injuring yourself while working at heights this kind of work should not be done by unqualified individuals When this kind of work must be carried ...

Page 4: ...erson 1 to refit the unit Do not set the circuit breaker to the ON position until the unit has been refitted Do not move or repair any unit by yourself Since there is high voltage inside the unit you may get electric shock when removing the cover and main unit Do not modify the products Do not also disassemble or modify the parts It may cause a fire electric shock or injury Relocation When the Air...

Page 5: ...ndle with packing band or may get injured in case of broken band 2 cartons 91 kg 2 Part Names Air to Air Heat Exchanger with DX Coil Unit Separately sold parts Remote controller for the Air to Air Heat Exchanger with DX Coil Unit NRC 01HE SA Supply air RA Return air EA Exhaust air OA Outdoor air Inspection cover for the heat exchange element Earth screw in electrical control box Drain hole Connect...

Page 6: ...X Coil Unit Outdoor unit Remote controller NRC 01HE RBC AMT32E Air conditioner Air conditioner Air to Air Heat Exchanger with DX Coil Unit Air to Air Heat Exchanger with DX Coil Unit When the Air to Air Heat Exchanger with DX Coil Unit system linked with indoor air conditioners is used set the Air to Air Heat Exchanger with DX Coil Unit as Follower referring to Setting the address manually using t...

Page 7: ...he remote controller display after pushing the button 5 button Filter reset button Resets FILTER indication after cleaning 6 button Power save operation Use to initiate power saving mode Display section Operation section 1 3 5 2 6 4 7 button Swing Louver direction button 1 8 Operation lamp Lights up during operation Blinks when an error occurs or the protective device activates 9 button Turns on t...

Page 8: ... mode 17 Louver lock indicator 1 18 UNIT No indicator The number of the Air to Air Heat Exchanger with DX Coil Unit selected using the UNIT button or that of the unit in which an error has occurred 19 Central control indicator Displayed when a central control device such as a central controller is also used If the central control device prohibits the use of local remote controllers blinks when any...

Page 9: ... the outdoor air exhaustion Inflow of humidity and smells from the toilet and kitchen is reduced When SA EA is selected the volume of the outdoor air exhaustion is larger than that of the indoor air supply Outflow of smells and floating bacteria into a corridor or other places is reduced Consult your dealer if the setting of the air volume imbalance seems incorrect Changing ventilation mode 1 Push...

Page 10: ...mount of time has passed between the nighttime heat purge operation becoming on standby and the monitoring operation starting The time is set between 1 48 hours in 1 hour steps 2 The indoor temperature is 3 C or more higher than the outdoor temperature and the indoor temperature is 2 C or more higher than the temperature set for the operation The conditions to pause the nighttime heat purge operat...

Page 11: ...s Hours 7 Installation Location Do not install the unit in places where the outside temperature falls below 5 C Avoid installing near machines emitting high frequency waves Not suitable for chemical plants such as liquefied carbon dioxide refrigerant plants A failure may occur in certain locations such as the following Areas with large amount of oil droplets including machine oil or vapors Salty a...

Page 12: ...et of the indoor unit is blocked NOTE When the protective device activates turn off the power switch remove the cause and then restart running Cooling Heating operations Each unit can be controlled individually However indoor units connected to the same outdoor unit cannot perform cooling and heating simultaneously When you attempt simultaneous operation indoor units performing cooling are stopped...

Page 13: ...t exchanger etc expand and contract slightly due to change of temperature indication is lit When cooling operation cannot be performed because another indoor unit performs heating operation Is outdoor temperature out of operation temperature range indication is lit When the manager of the Air to Air Heat Exchanger with DX Coil Unit has fixed the operation to COOL or HEAT and an operation contrary ...

Page 14: ...the indoor unit will be deleted 3 After confirmation push button to return to the usual display Check code Indoor unit No in which an error occurred 3 2 1 11Specifications Model with a humidifier Model without a humidifier Sound Power Level is less than 70 dBA MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE MMD VNK1002HEXE2 Type Function Cooling and heating dual purpose type Unit configuration Discr...

Page 15: ...chinery described below Generic Denomination Air conditioner Air to Air Heat Exchanger with DX Coil Unit Model type MMD VNK502HEXE MMD VNK802HEXE MMD VNK1002HEXE MMD VNK1002HEXE2 MMD VN502HEXE MMD VN802HEXE MMD VN1002HEXE MMD VN1002HEXE2 Commercial name TOSHIBA Air to Air Heat Exchanger with DX Coil Unit Complies with the provisions of the Machinery Directive Directive 2006 42 EC and the regulatio...

Page 16: ...CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom 00ET99915201_00Ta book Page 29 Tuesday February 15 2011 6 45 PM ...

Reviews: