22
5-3. Hot water cylinder unit
1 2
TB03 (230 V)
A B
TB06 (TTW)
Supply 220 - 230 V from hydro unit
Cable size 1.5 mm
2
(minimum)
To hydro unit
Green /
Yellow
Blue
Double pole thermal cut out
Blue
Brown
Brown
TTW sensor
Hot water cylinder heater
AMP Air Conditioning
www.ampair.co.uk | [email protected]